Optimizing virtual monoenergetic imaging for dual‑energy CT venography assessment of intracranial venous sinus stents.

Joel Kosowan, Timothy Reynold Lim, Akhil Nair, Asutosh Sahu, Vinu Mathew, Yingming Amy Chen, Vitor Mendes Pereira, Nicole Cancelliere, Shobhit Mathur

Abstract read
PubMed Publisher
In one paragraph

Article in Neuroradiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Joel KosowanDepartment of Medical Imaging, St. Michael's Hospital, Toronto, Canada.
Timothy Reynold LimDepartment of Medical Imaging, St. Michael's Hospital, Toronto, Canada.
Akhil NairDepartment of Medical Imaging, St. Michael's Hospital, Toronto, Canada.
Asutosh SahuDepartment of Medical Imaging, St. Michael's Hospital, Toronto, Canada.
Vinu MathewDepartment of Medical Imaging, St. Michael's Hospital, Toronto, Canada.
Yingming Amy ChenDepartment of Medical Imaging, St. Michael's Hospital, Toronto, Canada.
Vitor Mendes PereiraDepartment of Neurosurgery, St. Michael's Hospital, Toronto, Canada.
Nicole CancelliereDepartment of Neurosurgery, St. Michael's Hospital, Toronto, Canada.
Shobhit MathurDepartment of Medical Imaging, St. Michael's Hospital, Toronto, Canada. Shobhit.Mathur@unityhealth.to.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo determine a practical virtual monoenergetic imaging (VMI) energy range that improves in‑stent lumen assessment and reduces metal‑related artifacts on dual‑energy CT venography (DECT‑CTV) after intracranial venous sinus stenting.

methodsRetrospective single‑center study including 10 patients (13 stents) who underwent DECT‑CTV after venous sinus stenting for idiopathic intracranial hypertension or pulsatile tinnitus. VMI series were reconstructed from 40 to 140 keV in 10‑keV increments. Two neuroradiologists independently scored in‑stent lumen visibility and beam‑hardening/streak artifacts (5‑point Likert). Quantitative analysis used standardized ROI measurements (3 in‑stent and 2 adjacent out‑of‑stent ROIs per stent per keV) and derived metrics including in‑stent attenuation, background noise, CNR, SNR, and dCT_in-out (in‑stent minus out‑of‑stent attenuation).

resultsQualitatively, both readers preferred intermediate‑high energies (90-100 keV) for overall interpretability. Quantitatively, in‑stent attenuation decreased from 1180.7 ± 245.5 HU (40 keV) to 112.5 ± 15.7 HU (140 keV). Noise and dCT_in-out decreased with increasing energy, whereas CNR decreased with increasing energy. SNR showed no statistically significant differences across energies.

conclusionFor intracranial venous sinus stents on DECT‑CTV, VMI around 90-100 keV provided the best perceived balance between lumen accessibility and artifact suppression. Findings require validation in larger cohorts with device‑specific subgroup analyses and complementary artifact indices.

Indexed as

Computed Tomography AngiographyCranial SinusesPhlebographyStentsAdultAgedArtifactsContrast MediaFemaleHumansMaleMiddle AgedPseudotumor CerebriRadiographic Image Interpretation, Computer-AssistedRadiography, Dual-Energy Scanned ProjectionRetrospective StudiesContrast MediaArtifactsDual‑Energy computed tomographyIdiopathic intracranial hypertensionVenous sinus stentingVirtual monoenergetic imaging