Evidence map›Paper›PMID 41710536›Full record

ArticleFrontiers in bioengineering and biotechnology2026

The influence of different surface texture parameters on the cell proliferation and adhesion early behaviors on the surface of titanium alloy.

Fuqiang Lai, Changsheng Cao, Linfeng Xie, Mingxuan Shang, Wenge Liu, Yumei Li, Zhihuang Qiu, Liangwan Chen

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Fuqiang LaiDepartment of Cardiovascular Surgery, Fujian Medical University Union Hospital, Fuzhou, Fujian, China.
Changsheng CaoSchool of Mechanical Engineering and Automation, Fuzhou University, Fuzhou, Fujian, China.
Linfeng XieDepartment of Cardiovascular Surgery, Fujian Medical University Union Hospital, Fuzhou, Fujian, China.
Mingxuan ShangSchool of Mechanical Engineering and Automation, Fuzhou University, Fuzhou, Fujian, China.
Wenge LiuDepartment of Orthopedics, Fujian Medical University Union Hospital, Fuzhou, Fujian, China.
Yumei LiDepartment of Cardiovascular Surgery, Fujian Medical University Union Hospital, Fuzhou, Fujian, China.
Zhihuang QiuDepartment of Cardiovascular Surgery, Fujian Medical University Union Hospital, Fuzhou, Fujian, China.
Liangwan ChenDepartment of Cardiovascular Surgery, Fujian Medical University Union Hospital, Fuzhou, Fujian, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Current clinical practice has extensively validated the efficacy of left ventricular assist devices (LVADs) in managing end-stage heart failure. A persistent challenge across all ventricular assist systems involves achieving optimal biocompatibility at the critical interface between the LVAD outlet and myocardial tissue. In this study, femtosecond laser processing (FLP) technology was utilized to engineer microtextured surfaces with controlled geometric parameters on the titanium alloy surface. The experimental design systematically assessed surface morphology and compositional variations for four distinct patterns (circular, triangular, square, hexagonal) and three texture depths (10, 20, 40 μm). FLP demonstrated favourable microstructural fabrication quality, producing defined pattern boundaries with minimal thermal impact on adjacent regions. While all textured surfaces exhibited characteristic periodic processing marks at their bases, increased texture depth correlated with progressive roughness amplification in these basal regions. Elemental analysis revealed that oxygen enrichment specifically along texture peripheries compared to untextured surfaces. Cellular early response studies demonstrated that surface texturing significantly enhanced cardiac fibroblasts adhesion on titanium substrates while concurrently modifying fibroblast growth patterns. Quantitative analysis identified 20 μm as the optimal texture depth for cellular proliferation and adhesion, outperforming both shallower (10 μm) and deeper (40 μm) configurations. Geometric comparisons indicated that square patterns induced the best pronounced pro-proliferative effects, followed by hexagonal patterns. Mechanistic observations suggest that surface micro-roughness facilitates initial cell adhesion, with subsequent proliferation biodynamics being governed by topographical guidance effects. These findings establish clear structure-function relationships between engineered surface parameters and biological responses, providing significant insights for LVAD surface treatment and optimization.

Indexed as

cell proliferation and adhesionfemtosecond laser processingparameter optimizationsurface texturetitanium alloy

Identifiers

PMID41710536
PMCPMC12909512

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.