Evidence map›Paper›PMID 41708490›Full record

ArticleMagnetic resonance in medicine2026

A Spatio-Temporal Diffusion Model for Cardiac Real-Time Imaging.

Oliver Schad, Julius Frederik Heidenreich, Nils Petri, Viktor Hartung, Alena Kollmann, Thorsten Alexander Bley, Peter Nordbeck, Bernhard Petritsch, Tobias Wech

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Oliver SchadDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.ORCID 0009-0004-0646-8293
Julius Frederik HeidenreichDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.ORCID 0000-0002-0683-7982
Nils PetriDepartment of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany.
Viktor HartungDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.
Alena KollmannDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.
Thorsten Alexander BleyDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.ORCID 0000-0001-9311-7985
Peter NordbeckDepartment of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany.ORCID 0000-0002-2560-4068
Bernhard PetritschDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.ORCID 0000-0002-9909-1592
Tobias WechDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.ORCID 0000-0002-2813-7100

Funding

Bundesministerium für Bildung und Forschung 05M20WKAInterdisziplinäres Zentrum für Klinische Forschung, Universitätsklinikum Würzburg F-437
6 · The paper itself

Abstract

purposeReal-time imaging of cardiac function is favorable due to shorter scan times and becomes necessary when arrhythmia or inability to hold breath leads to insufficient quality of electrocardiogram (ECG)-gated Cartesian cine. However, comparable spatio-temporal resolution can only be achieved in undersampled settings, which in turn demand performant reconstruction methods. This study investigates image quality improvements using a novel spatio-temporal diffusion-based reconstruction, applied to accelerated spiral real-time acquisitions.

methodsIn a clinical study, real-time acquisition was performed using accelerated spiral sampling patterns acquired during breath hold and free-breathing. Retrospective binning enabled calculation of segmented spiral cine images, which were used to train a spatio-temporal diffusion model. Reconstruction of accelerated acquisitions was performed using the proposed model, as well as a 2D spatial diffusion model and compressed sensing-based techniques for comparison. Reconstruction quality was assessed by calculating quantitative image metrics for breath-held data and by means of an expert-reader study for free-breathing scans.

resultsReal-time acquisitions enabled significantly shorter scan durations in comparison to clinical cine, with improved quality for participants with irregular heartbeats. Quantitative image metrics indicate superior image quality of the proposed method compared to the baseline methods. Expert reader scores imply consistent sharpness and reduced apparent noise for the proposed model.

conclusionIncluding temporal information within the diffusion model improved consistency between frames, reduced noise, and preserved sharpness in the reconstructions of undersampled spiral acquisitions. Long reconstruction times and demanding computational burdens are obstacles to overcome.

Indexed as

Diffusion Magnetic Resonance ImagingHeartImage Processing, Computer-AssistedMagnetic Resonance Imaging, CineAlgorithmsBreath HoldingComputer SystemsElectrocardiographyHumansImage Interpretation, Computer-AssistedMaleReproducibility of ResultsSpatio-Temporal Analysiscardiac imagingdiffusion modelsgenerative modelingheartmachine learningmagnetic resonance imaging (MRI)video diffusion model

Identifiers

PMID41708490
PMCPMC13049260

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.