Evidence map›Paper›PMID 41704283›Full record

ArticleFrontiers in public health2025

Intersubject variability in a comprehensive numerical assessment of operator electromagnetic exposure to TMS.

S D'Agostino, M Colella, R Falsaperla, M Liberti, F Apollonio

Abstract read
In one paragraph

Article in Frontiers in public health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

S D'AgostinoDepartment of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, Rome, Italy.
M ColellaDepartment of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, Rome, Italy.
R FalsaperlaDepartment of Occupational and Environmental Medicine, Epidemiology and Hygiene, Italian National Institute for Insurance Against Accidents at Work, Rome, Italy.
M LibertiDepartment of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, Rome, Italy.
F ApollonioDepartment of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, Rome, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Transcranial magnetic stimulation (TMS) is increasingly used in clinical and research settings, often requiring the operator to remain in close proximity to the stimulation coil. While regulatory guidelines exist for patient safety, the workplace exposure assessment, particularly its dependence on operator anatomy, remains limited. This study aimed to comprehensively evaluate the electric field (E-field) induced in TMS operators under realistic working conditions, with a focus on how inter-subject anatomical variability affects compliance with international safety guidelines. Methods: Numerical simulations were performed using four anatomically detailed virtual human models exposed to a circular TMS coil in clinically relevant positions. Two coil heights (chest and abdomen) and three coil-to-operator distances (12 cm, 22 cm, 40 cm) were analyzed. The induced E-field was computed using magneto-quasi-static solvers, and the results were compared with the ICNIRP basic restriction for occupational exposure (1.13 V/m) and with the experimental threshold for peripheral neurostimulation (4 V/m). Whole-body percentiles, localized distributions, and anatomical cross-sections were evaluated to characterize inter-subject variability. Results: At 40 cm, all models and exposure scenarios were compliant with ICNIRP limits. At 22 cm, most configurations remained compliant, though some models slightly exceeded the reference level, particularly in the abdominal region. At 12 cm, the induced E-field systematically exceeded the occupational limit across all models, while remaining below the neurostimulation threshold. Anatomical features, such as subcutaneous adipose tissue thickness and tissue discontinuities, were found to strongly influence field localization and intensity, especially at closer distances. Conclusion: Operator exposure to TMS is influenced by both coil positioning and individual anatomical characteristics. While increasing distance ensures compliance and reduces variability, closer configurations may require tailored assessments or mitigation strategies. These findings highlight the importance of considering inter-subject variability in the evaluation of operator exposure and suggest that anatomical models may underestimate variability in real clinical contexts. A limitation of this study is the assumption of a static operator not manually holding the coil, a common condition in clinical practice that warrants further investigation.

Indexed as

Electromagnetic FieldsOccupational ExposureTranscranial Magnetic StimulationComputer SimulationHumansWorking Conditionshuman variabilityintersubject comparisonnumerical dosimetryoccupational exposure assessmenttranscranial magnetic stimulation

Identifiers

PMID41704283
PMCPMC12908317

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.