ArticleJournal of applied clinical medical physics2026
Evaluation of the InTempo path set for CyberKnife prostate and lung SBRT: A single-institution experience.
Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Evaluation of the InTempo path set for CyberKnife prostate and lung SBRT: A single-institution experience.Journal of applied clinical medical physics · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe InTempo adaptive imaging system is an important component of the Accuray CyberKnife System, designed to enhance the system's ability to track and correct tumor motion during treatment. However, a limitation of this feature is the reduction of available nodes for treatment planning. The impact of a reduced number of nodes on the quality of InTempo-based treatment plans has not previously been evaluated. This retrospective study aims to compare the dosimetry of CyberKnife plans with and without The InTempo path set for both prostate and lung stereotactic body radiotherapy (SBRT).
methodsThis study included twelve consecutive prostate SBRT patients and twenty selected lung SBRT patients. The selection criteria for the 20 lung patients were motivated by being able to construct a data set representative of common treatment tracking methods and dose prescriptions. To evaluate the impact of InTempo imaging, treatment plans were re-optimized using the same optimization parameters and machine settings, except for the path set with the maximum number of nodes. To ensure a fair comparison, the study plans were prescribed using identical planning target volume coverage as the clinical treatment plans. Statistical analyses were performed using mean and standard deviation, dose metric plots, and a two-sided Wilcoxon signed rank test with multiple testing correction to compare dose metrics between different path sets.
resultsNo statistically significant differences were observed among the Prostate, Prostate_Short, and their corresponding InTempo path sets in at least 8 of the 14 evaluated plan metrics, including prostate clinical tumor volume (CTV) V40Gy(%), conformity index, and homogeneity index. For example, the mean prostate CTV V40Gy (%) for the Prostate, Prostate_Short, and their corresponding InTempo path sets was 90.8 ± 4.7, 89.4 ± 4.7, 90.2 ± 3.9, 91.0 ± 7.0, respectively. However, compared with the Prostate path set, the Prostate_InTempo path set exhibited a statistically significant reduction in delivery time (p = 0.0010), number of beams, and bladder V18Gy (%), along with a statistically significant increase in the number of imaging beams (p = 0.0010). Additionally, Prostate_Short demonstrated statistically significant reductions in delivery time and number of beams compared with the Prostate path set, while the number of imaging beams remained statistically equivalent. In contrast, the Reduced_Prostate and Reduced_Prostate_InTempo sets consistently resulted in inferior dosimetric outcomes, with several plans deemed unoptimizable due to insufficient node availability. For lung SBRT, statistically significant differences were observed in delivery time and the number of imaging beams between plans with and without InTempo. However, no statistical differences were found in dose distribution metrics between these two lung groups.
conclusionsInTempo-compatible path sets do not significantly compromise plan quality for prostate or lung SBRT, provided adequate node availability. Specifically, the Prostate_InTempo and Prostate_Short path sets demonstrated a reduction in delivery time and an increase in adaptive imaging frequency compared with the Prostate path set. However, the Reduced_Prostate and Reduced_Prostate_InTempo result in inferior plan quality and reduced deliverability and should be used with caution. These findings support the selective use of InTempo imaging in SBRT planning without sacrificing dosimetric integrity.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.