Evidence map›Paper›PMID 41701458›Full record

ArticleAnalytical sciences : the international journal of the Japan Society for Analytical Chemistry2026

Fundamental characteristics of voltage-modulated helium plasma for multi-element analysis in low-volume samples.

Yuya Shimizu, Masaya Tahara, Yuwa Ando, Kai Fukuchi, Akane Yaida, Yukiko Moriiwa, Kazuhiro Morioka, Atsushi Shoji, Akitoshi Okino

Abstract read
In one paragraph

Article in Analytical sciences : the international journal of the Japan Society for Analytical Chemistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yuya ShimizuLaboratory for Future Interdisciplinary Research and Technology (FIRST), Institute of Science Tokyo, 4259-J2-32, Midori-ku, Nagatsuta, Yokohama, 226-8501, Japan. y-shimizu@plasma.es.titech.ac.jp.
Masaya TaharaLaboratory for Future Interdisciplinary Research and Technology (FIRST), Institute of Science Tokyo, 4259-J2-32, Midori-ku, Nagatsuta, Yokohama, 226-8501, Japan.
Yuwa AndoLaboratory for Future Interdisciplinary Research and Technology (FIRST), Institute of Science Tokyo, 4259-J2-32, Midori-ku, Nagatsuta, Yokohama, 226-8501, Japan.
Kai FukuchiLaboratory for Future Interdisciplinary Research and Technology (FIRST), Institute of Science Tokyo, 4259-J2-32, Midori-ku, Nagatsuta, Yokohama, 226-8501, Japan.
Akane YaidaLaboratory for Future Interdisciplinary Research and Technology (FIRST), Institute of Science Tokyo, 4259-J2-32, Midori-ku, Nagatsuta, Yokohama, 226-8501, Japan.
Yukiko MoriiwaSchool of Pharmacy, Tokyo University of Pharmacy and Life Sciences, Hachioji, 1432-1 Horinouchi, Hachioji, Tokyo, 192-0392, Japan.
Kazuhiro MoriokaSchool of Pharmacy, Tokyo University of Pharmacy and Life Sciences, Hachioji, 1432-1 Horinouchi, Hachioji, Tokyo, 192-0392, Japan.
Atsushi ShojiSchool of Pharmacy, Tokyo University of Pharmacy and Life Sciences, Hachioji, 1432-1 Horinouchi, Hachioji, Tokyo, 192-0392, Japan.
Akitoshi OkinoLaboratory for Future Interdisciplinary Research and Technology (FIRST), Institute of Science Tokyo, 4259-J2-32, Midori-ku, Nagatsuta, Yokohama, 226-8501, Japan. aokino@first.iir.isct.ac.jp.

Funding

KAKENHI 22H04973
6 · The paper itself

Abstract

High-sensitivity multi-element analysis of low-volume samples remains a challenge in plasma-based analytical methods because optimal excitation conditions differ among elements and conventional steady-state plasma require relatively large sample volumes. In this study, we developed a voltage-modulated helium plasma in which the applied voltage was continuously varied over short time intervals to dynamically control the plasma energy state. The fundamental characteristics of plasma were evaluated in terms of gas temperature, emission spectrum, and excitation temperature. Under steady-state operation, plasma length, gas temperature, and excitation temperature increased with increasing applied voltage, confirming that the plasma energy state can be controlled by applied voltage. In the voltage-modulated plasma, emission intensity and excitation temperature responded rapidly to voltage changes, enabling the generation of plasma with different energy states within a short time. Notably, the excitation temperature, one of the key indicators of the plasma energy state, was dynamically varied over a wide range of approximately 1900–3600 K. In addition, voltage modulation effectively suppressed the overall increase in plasma gas temperature caused by Joule heating, while maintaining high-energy plasma states during high-voltage periods. These results demonstrate that voltage-modulated plasma generation enables rapid switching between energy states optimized for different elements, offering a practical strategy for high-sensitivity multi-element analysis with significantly reduced sample consumption. The proposed method is particularly suitable for the analysis of small-volume and heat-sensitive samples.

Indexed as

Low-volume samplesMass spectrometryMicroplasmaMulti-element analysisOptical emission spectroscopyVoltage-modulated plasma

Identifiers

PMID41701458
PMCPMC13013168

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.