Added value of dynamic SPECT/CT after kidney transplantation using a 3D-ring CZT-based camera: a case report.

Anita A Harteveld, Alina van de Burgt, Dennis A Hesselink, Frederik A Verburg

Abstract read
In one paragraph

Article in EJNMMI research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Anita A HarteveldDepartment of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands. a.harteveld@erasmusmc.nl.ORCID http://orcid.org/0000-0002-3379-0710
Alina van de BurgtDepartment of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands.
Dennis A HesselinkDepartment of Internal Medicine, Division of Nephrology and Transplantation, Erasmus MC, Rotterdam, The Netherlands.
Frederik A VerburgDepartment of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDynamic two-dimensional (2D) planar renal scintigraphy is a widely used imaging modality for evaluating renal function, though its anatomical and quantitative accuracy is limited by overlapping structures. Recent advancements in single photon emission computed tomography/computed tomography (SPECT/CT) technology employ a multi-detector cadmium-zinc-telluride (CZT) ring configuration. This eliminates the need for camera rotation around the patient, reducing acquisition time and enabling high temporal resolution dynamic three-dimensional (3D) imaging. This technology may be particularly beneficial for kidney transplant patients. CASE PRESENTATION: We present a case of a 44-year-old male who underwent dynamic SPECT/CT renal scintigraphy with impaired urinary excretion following post kidney transplantation.

conclusionsDynamic SPECT/CT using a 3D-ring CZT-based camera demonstrated added diagnostic value in the presented renal scintigraphy application.