Evidence map›Paper›PMID 41699339›Full record

ArticleAnnals of biomedical engineering2026

Controlled External Thigh Compression: A Feasible Method to Simulate Venous Hemodynamic Alterations Resembling Deep Vein Thrombosis.

Rimvydas Eitminavičius, Rytis Jurkonis, Sami Maja, Roni Ahola, Neringa Balčiūnienė, Antti Vehkaoja, Vaidotas Marozas, Andrius Rapalis

Abstract read
In one paragraph

Article in Annals of biomedical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Rimvydas EitminavičiusBiomedical Engineering Institute, Kaunas University of Technology, K. Barsausko St. 59, 51423, Kaunas, Lithuania. rimvydas.eitminavicius@ktu.lt.ORCID http://orcid.org/0009-0009-4682-8878
Rytis JurkonisBiomedical Engineering Institute, Kaunas University of Technology, K. Barsausko St. 59, 51423, Kaunas, Lithuania.ORCID http://orcid.org/0000-0002-9481-1773
Sami MajaFaculty of Medicine and Health Technology, Tampere University, Korkeakoulunkatu St. 3, 33720, Tampere, Finland.ORCID http://orcid.org/0009-0009-9052-3780
Roni AholaFaculty of Medicine and Health Technology, Tampere University, Korkeakoulunkatu St. 3, 33720, Tampere, Finland.ORCID http://orcid.org/0009-0000-3533-9766
Neringa BalčiūnienėClinic of Neurosurgery, Lithuanian University of Health Sciences, Mickeviciaus St. 9, 44307, Kaunas, Lithuania.
Antti VehkaojaFaculty of Medicine and Health Technology, Tampere University, Korkeakoulunkatu St. 3, 33720, Tampere, Finland.ORCID http://orcid.org/0000-0003-3721-3467
Vaidotas MarozasBiomedical Engineering Institute, Kaunas University of Technology, K. Barsausko St. 59, 51423, Kaunas, Lithuania.ORCID http://orcid.org/0000-0002-6879-5845
Andrius RapalisBiomedical Engineering Institute, Kaunas University of Technology, K. Barsausko St. 59, 51423, Kaunas, Lithuania.ORCID http://orcid.org/0000-0003-0183-5168

Funding

European Health and Digital Executive Agency Project 101137227 - ThrombUS
6 · The paper itself

Abstract

purposeDeep vein thrombosis (DVT) poses significant health risks, including potentially fatal pulmonary embolism. Current clinical practice relies heavily on ultrasonography, requiring a skilled specialist. Alternative methods, such as light reflection rheography (LRR) and venous occlusion plethysmography (VOP), are non-invasive and simple; however, studies report limited consistency and standardization. The development of biosignal-based diagnostic tools is constrained by the inherent risks of DVT, including embolization, and challenges in patient recruitment. The ability to simulate DVT-like conditions would aid in developing and testing alternative screening methods. This study aims to present a simulation method of venous hemodynamic alterations resembling deep vein thrombosis using controlled external thigh compression with ultrasonic visualization.

methodsData collection with thirty healthy volunteers was conducted in a laboratory using a commercially available system VasoScreen 5000-4000 to record LRR and VOP signals. Vein stenosis at varying levels was induced through controlled external thigh compression under ultrasonic guidance.

resultsThe experimental simulation showed statistically significant but small changes in LRR parameters across different stenosis levels. In comparison, VOP results showed greater differences across stenosis levels, with 70% and 100% performing the best. In these cases, 47% and 70% of the measurements, respectively, were below the normal reference limit, with a notably increased outflow time constant, compared to the baseline measurements, where it remained low despite varying venous capacity.

conclusionPresented hemodynamic alterations demonstrated to be a feasible option for simulating DVT-like conditions via controlled external pressure on the thigh.

Indexed as

HemodynamicsModels, CardiovascularThighVenous ThrombosisAdultFemaleHumansMaleUltrasonographyDeep vein thrombosisLight reflection rheographyVenous hemodynamicsVenous occlusion plethysmographyVenous stenosis

Identifiers

PMID41699339
PMCPMC13290885

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.