Evidence map›Paper›PMID 41696751›Full record

ArticleCase reports in plastic surgery & hand surgery2026

Chest wall stabilization following hemi-sternectomy assisted by 3D printed model.

Phillip L Nichols, Caleb W Brown, Derek C Wenger, Jennifer M Osher, Jeremy M Powers

Abstract readCase Reports
In one paragraph

Article in Case reports in plastic surgery & hand surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Phillip L NicholsQuillen College of Medicine, East Tennessee State University, Johnson City, TN, USA.ORCID https://orcid.org/0009-0008-1470-9658
Caleb W BrownQuillen College of Medicine, East Tennessee State University, Johnson City, TN, USA.ORCID https://orcid.org/0009-0007-7541-8320
Derek C WengerQuillen College of Medicine, East Tennessee State University, Johnson City, TN, USA.ORCID https://orcid.org/0009-0003-9084-4724
Jennifer M OsherQuillen College of Medicine, East Tennessee State University, Johnson City, TN, USA.ORCID https://orcid.org/0000-0001-7912-5508
Jeremy M PowersDepartment of Surgery, Division of Plastic and Reconstructive Surgery, Quillen College of Medicine, East Tennessee State University, Johnson City, TN, USA.ORCID https://orcid.org/0000-0001-6839-0058

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The incidence of deep sternal wound infection post-sternotomy is 1.6%. Treatment with sternectomy or hemi-sternectomy can result in exposed thoracic organs, chest wall and shoulder girdle instability, reduced upper extremity function and disability. Various materials and soft tissue techniques are available for chest wall reconstruction; however, the use of a 3D-printed model to facilitate preoperative bending of titanium plating systems for sternal reconstruction has not been previously reported. A 51-year-old female presented to the plastic surgery clinic with a history of coronary artery bypass grafting complicated by sternal osteomyelitis. A left hemi-sternectomy was performed to treat the infection, after which the patient developed chronic pain and shoulder instability. The patient was referred to plastic surgery to consider options for combined sternal stabilization and flap coverage. A polyamide 3D-printed model of the sternum and ribcage was produced, followed by pre-operative bending of sternal-spanning long rib plates for use in the operating room. The model and the pre-bent plates were sterilized and brought to surgery. After elevation of pectoralis muscle flaps and exposure, the pre-bent plates were directly applied to the rib cage with minimal modification, thus obtaining the pre-planned reduction of the sternum/ribcage and saving a significant amount of time in the operating room. The patient made a good recovery from the operation with significant improvement of chest wall stability, improvement of shoulder function, and a decrease in chest discomfort. This report details the application of 3D printing to increase the precision and efficiency of chest wall stabilization.

Indexed as

3D printinghemi-sternectomyreconstructionSternal reconstructionsternectomy

Identifiers

PMID41696751
PMCPMC12895858

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.