Evidence map›Paper›PMID 41696038›Full record

ArticleEuropean heart journal. Case reports2026

Atrial lead entanglement during transcatheter mitral valve-in-ring implantation in patient with dual-chamber implantable cardioverter-defibrillator: case report.

Suryo Ardi Hutomo, Xiang Chen, Bin Wang, Yan Er Yao, Yan Wang

Abstract readCase Reports
In one paragraph

Article in European heart journal. Case reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Suryo Ardi HutomoDepartment of Cardiology, Xiamen Cardiovascular Hospital Xiamen University, 2999 Jinshan Road, Huli District, Xiamen City, Fujian Province 361004, China.ORCID https://orcid.org/0000-0002-0592-3117
Xiang ChenDepartment of Cardiology, Xiamen Cardiovascular Hospital Xiamen University, 2999 Jinshan Road, Huli District, Xiamen City, Fujian Province 361004, China.ORCID https://orcid.org/0000-0003-0306-0976
Bin WangDepartment of Cardiology, Xiamen Cardiovascular Hospital Xiamen University, 2999 Jinshan Road, Huli District, Xiamen City, Fujian Province 361004, China.
Yan Er YaoDepartment of Cardiology, Xiamen Cardiovascular Hospital Xiamen University, 2999 Jinshan Road, Huli District, Xiamen City, Fujian Province 361004, China.
Yan WangDepartment of Cardiology, Xiamen Cardiovascular Hospital Xiamen University, 2999 Jinshan Road, Huli District, Xiamen City, Fujian Province 361004, China.ORCID https://orcid.org/0000-0001-9976-848X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Ring annuloplasty failure after mitral valve repair frequently occurs after long-term follow up. Valve-in-ring transcatheter mitral valve replacement (TMVR) is an emerging therapeutic option for this high surgical risk condition. While a dual-chamber implantable cardioverter-defibrillator (ICD) is frequently utilized for sudden cardiac death prevention in this population, valve-in-ring TMVR intraprocedural difficulty associated with atrial lead presence is rarely known. Case summary: A 76-year-old male, with history of coronary artery bypass graft surgery and mitral ring annuloplasty experienced recurrence of severe mitral regurgitation. Due to high surgical mortality risk and unsuitable anatomy of mitral valve for transcatheter edge-to-edge repair, this patient underwent mitral valve-in-ring TMVR. Using transvenous-transseptal access, a 26 mm SAPIEN-3 prosthetic valve was delivered to the mitral area. However, as the patient has a history of dual-chamber ICD, a prosthetic valve cannot pass through during delivery, due to atrial lead entanglement. To overcome this difficulty, atrial septum balloon dilatation manoeuvre was done to facilitate valve delivery, which resulted in successful prosthetic valve delivery and deployment at the mitral position with satisfactory results. Discussion: Valve delivery difficulty due to atrial lead entanglement can occur during valve-in-ring TMVR in patients with dual-chamber ICD implantation history. Atrial septum balloon dilatation can be performed to overcome this problem.

Indexed as

Atrial leadCase reportDual-chamber ICDMitral valve interventionRing annuloplasty failureValve-in-ring

Identifiers

PMID41696038
PMCPMC12903476

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.