Evidence map›Paper›PMID 41695906›Full record

ArticleSpine surgery and related research2026

Biomechanical Evaluations of Novel Clip-Type Implants for Cervical Double-Door Laminoplasty, Compared with Conventional Hydroxyapatite Spacers: A Cadaveric Study.

Takahiro Mui, Sachiko Kawasaki, Hideki Shigematsu, Masaki Ikejiri, Takuya Sada, Apichat Sinthubua, Treerat Gumpangseth, Pasuk Mahakkanukrauh, Yasuhito Tanaka

Abstract read
In one paragraph

Article in Spine surgery and related research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Takahiro MuiDepartment of Orthopaedic Surgery, Nara Medical University, Nara, Japan.
Sachiko KawasakiDepartment of Orthopaedic Surgery, Nara Medical University, Nara, Japan.
Hideki ShigematsuDepartment of Orthopaedic Surgery, Nara Medical University, Nara, Japan.
Masaki IkejiriDepartment of Emergency and Critical Care Medicine, Nara Medical University, Nara, Japan.
Takuya SadaDepartment of Orthopaedic Surgery, Nara Medical University, Nara, Japan.
Apichat SinthubuaDepartment of Anatomy, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.
Treerat GumpangsethDepartment of Anatomy, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.
Pasuk MahakkanukrauhDepartment of Anatomy, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.
Yasuhito TanakaDepartment of Orthopaedic Surgery, Nara Medical University, Nara, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Double-door laminoplasty is a common surgical approach; however, implant displacement and hinge fractures can cause lamina closure, leading to unfavorable outcomes. A novel clip-type implant has been introduced to improve rigid fixation safely; however, its biomechanical stability, compared with that of hydroxyapatite (HA) spacers, has not yet been evaluated. Therefore, the aim of this study was to compare the mechanical stability of polyetheretherketone clip implants versus that of HA spacers in freshly frozen cadaveric cervical spines. Methods: Seven freshly frozen cervical spines were used in this study. Double-door laminoplasty was performed at the C3-C6 cervical vertebral level. Clip-type implants and HA spacers were alternately placed on each specimen. Strain gauges were used to measure lamina displacement and reaction force at 0-mm to 2.5-mm lateral displacement. The reaction forces between the clip implant and HA spacer groups were compared. Results: Polyetheretherketone clip-type implants had significantly higher reaction force values than HA spacers at all displacement levels (p<0.001). Clip-type implants exhibited a 1.5- to 1.7-times higher reaction force than that of spacers at the middle of the lamina and a 1.9- to 2.0-times higher reaction force than that of spacers at the tip of the lamina. Conclusions: Novel clip-type implants provide greater stability than HA spacers. To the best of our knowledge, this study is the first to demonstrate the superior biomechanical stability of clip implants.

Indexed as

biomechanicscadavercervical spineclipimplant stabilitylaminoplasty

Identifiers

PMID41695906
PMCPMC12895168

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.