Evidence map›Paper›PMID 41695014›Full record

ReviewCureus2026

Cerebral Embolic Protection During Transcatheter Aortic Valve Replacement: A Systematic Review of Effects on Diffusion-Weighted MRI Lesions, Clinical Stroke, and Early Cognition.

Fahad R Khan, Abid Ullah, Fazal Akbar, Kamran Aslam, Syed Alishan, Imran Ali

Abstract readReview
In one paragraph

Review in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Fahad R KhanInterventional Cardiology, Peshawar Institute of Cardiology, Peshawar, PAK.
Abid UllahCardiology, Manchester Royal Infirmary, Manchester, GBR.
Fazal AkbarInterventional Cardiology, Peshawar Institute of Cardiology, Peshawar, PAK.
Kamran AslamInterventional Cardiology, Peshawar Institute of Cardiology, Peshawar, PAK.
Syed AlishanInterventional Cardiology, Peshawar Institute of Cardiology, Peshawar, PAK.
Imran AliInterventional Cardiology, Peshawar Institute of Cardiology, Peshawar, PAK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cerebral embolic protection devices (CEPDs) are used during transcatheter aortic valve replacement (TAVR) to intercept or deflect embolic material generated during the procedure, with the goal of reducing neurologic injury. We systematically compared CEPD to no CEPD for periprocedural clinical stroke (≤72 hours or at discharge; disabling stroke when reported), diffusion-weighted magnetic resonance imaging (DW-MRI) surrogate lesions, and early cognitive change. We prioritized the ≤72-hour/at-discharge window because CEPDs act during the index procedure, and this time frame aligns with commonly used periprocedural stroke definitions, whereas later events may reflect additional post-discharge factors and were inconsistently reported across studies. PubMed and ScienceDirect were searched from inception; randomized trials and comparative cohort studies were eligible. The risk of bias was assessed using the revised Cochrane Risk of Bias tool (RoB 2) and Risk Of Bias In Non-randomized Studies of Interventions (ROBINS-I); the certainty of evidence was graded with Grading of Recommendations, Assessment, Development, and Evaluation (GRADE); and the protocol was prospectively registered (PROSPERO CRD420251120071). Given substantial clinical and methodological heterogeneity, findings were synthesized narratively. Nine studies met the inclusion criteria (seven randomized trials and two cohorts). Mechanistic trials generally reported fewer and/or smaller new DW-MRI lesions with CEPD use, particularly when supra-aortic vessel coverage was more complete. In the largest randomized trial to date, early any-stroke rates were similar between cerebral embolic protection and control, while disabling stroke showed a possible reduction with protection. Other Sentinel studies confirmed frequent debris capture and suggested reductions in lesion burden but did not demonstrate consistent early clinical benefit. Early cognition was assessed infrequently and with varied tools and time points; MISTRAL-C suggested less very-early decline associated with smaller lesion burden, whereas larger studies found no clear mean advantage. Because cognitive outcomes influence rehabilitation, functional recovery, and independence after TAVR, standardized cognitive assessment remains a key evidence gap. Overall, CEPD use appears to improve DW-MRI surrogate measures but has not shown a reliable reduction in overall periprocedural stroke; any potential benefit for disabling stroke remains uncertain. Certainty of evidence was moderate for any stroke, low to moderate for DW-MRI outcomes, and low for early cognition. These findings support selective rather than routine CEPD use and emphasize the need for coverage-verified trials with standardized neurologic and cognitive follow-up.

Indexed as

cerebral embolic protectioncognitiondw-mrisentinelstroketavrtriguard

Identifiers

PMID41695014
PMCPMC12906250

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.