Evidence map›Paper›PMID 41692253›Full record

ArticleThe Annals of thoracic surgery2026

Survival After Left Ventricular Assist Device: A Society of Thoracic Surgeons National Intermacs Database Risk Model Assessment.

J Hunter Mehaffey, Brandon A Singletary, Seth Lewis, Byron C Jaeger, Devin Koehl, Ryan Cantor, Ramaraju Rudraraju, Palak Shah, Francis D Pagani, James K Kirklin

Abstract read
In one paragraph

Article in The Annals of thoracic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

J Hunter MehaffeyWest Virginia University, Morgantown, West Virginia. Electronic address: james.mehaffey@wvumedicine.org.
Brandon A SingletaryKirklin Solutions, Birmingham, Alabama.
Seth LewisKirklin Solutions, Birmingham, Alabama.
Byron C JaegerWake Forest University, Winston-Salem, North Carolina.
Devin KoehlKirklin Solutions, Birmingham, Alabama.
Ryan CantorKirklin Solutions, Birmingham, Alabama.
Ramaraju RudrarajuKirklin Solutions, Birmingham, Alabama; Inova Schar Heart and Vascular, Falls Church, Virginia.
Palak ShahInova Schar Heart and Vascular, Falls Church, Virginia.
Francis D PaganiUniversity of Michigan, Ann Arbor, Michigan.
James K KirklinKirklin Solutions, Birmingham, Alabama; University of Alabama at Birmingham, Birmingham, Alabama.

Funding

Network for Cardiothoracic Surgical Investigations in Cardiovascular MedicineUM1HL088925 · NHLBI · UNIVERSITY OF VIRGINIA · PI BADHWAR, VINAY, KRON, IRVING L. · 2013 to 2025
$6.8M
NHLBI NIH HHS UM1 HL088925
6 · The paper itself

Abstract

backgroundSeveral left ventricular assist device (LVAD) risk models exist; however, currently, only 1 LVAD is available. Therefore, we assessed prognostic accuracy of including data from other durable LVADs vs fully magnetic devices only in 3-year survival models.

methodsAll patients receiving primary continuous flow LVADs in The Society of Thoracic Surgeons National Intermacs (Interagency Registry for Mechanically Assisted Circulatory Support) Database (January 2013-April 2023) were included. Patients were stratified into 3 cohorts: cohort 1, fully magnetic devices only, 2018-2023 (n = 12,449); cohort 2, hydrodynamic and magnetically levitated and axial flow devices, 2018-2023 (n = 3235); and cohort 3, hydrodynamic and magnetically levitated and axial flow devices, 2013-2017 (n = 14,019). Machine learning multivariable oblique random survival forests compared 3 models predicting 3-year survival in testing sets from the fully magnetic cohort. Model 1 included only cohort 1 patients; model 2 included cohorts 1 and 2; and model 3 included cohorts 1, 2, and 3.

resultsOf the patients with fully magnetic LVADs, 2552 (20.5%) died within 3 years of implantation. Model discrimination, assessed by mean time-dependent area under the curve, was similar for all 3 models (0.706, 0.700, and 0.706). Calibration evaluated by time-dependent delta Brier score demonstrated that model 1 had superior performance compared with model 2 (P = .016) and model 3 (P = .038), particularly after the first-year following implantation.

conclusionsModels including data from older/alternative durable LVADs showed similar or inferior performance compared with a model using fully magnetic device-only patients. These findings support current methodology including only patients receiving fully magnetic LVADs while also providing a framework for model comparisons in future device eras.

Indexed as

Heart-Assist DevicesHeart FailureAgedDatabases, FactualFemaleHumansMiddle AgedRegistriesRisk AssessmentSocieties, MedicalSurvival RateUnited States

Identifiers

PMID41692253
PMCPMC13478818

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.