Evidence map›Paper›PMID 41689727›Full record

ArticleMedical & biological engineering & computing2026

A multi-level segmentation-guided diffusion model for streak artifact reduction in routine non-contrast chest CT.

Jingxin Liu, Xinran Zhu, Zhangzhen Shi, Donghong An, Lihui Zu, Kailiang Cheng, Zhong Zhang

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jingxin Liu *Department of Radiology, China-Japan Union Hospital of Jilin University, 126 Xiantai Blvd, Changchun, 130033, China. jingxin@jlu.edu.cn.
Xinran ZhuDepartment of Radiology, China-Japan Union Hospital of Jilin University, 126 Xiantai Blvd, Changchun, 130033, China.
Zhangzhen ShiDepartment of Medical Oncology Ward I, China-Japan Union Hospital of Jilin University, 126 Xiantai Blvd, Changchun, 130033, China.
Donghong AnDepartment of Radiology, China-Japan Union Hospital of Jilin University, 126 Xiantai Blvd, Changchun, 130033, China.
Lihui ZuDepartment of Radiology, China-Japan Union Hospital of Jilin University, 126 Xiantai Blvd, Changchun, 130033, China.
Kailiang ChengDepartment of Radiology, China-Japan Union Hospital of Jilin University, 126 Xiantai Blvd, Changchun, 130033, China.
Zhong Zhang *Jilin Engineering Technology Research Center for Medical Imaging, China-Japan Union Hospital of Jilin University, 126 Xiantai Blvd, Changchun, 130033, China. mirotical@hotmail.com.ORCID http://orcid.org/0000-0002-9464-8662

Funding

the Jilin Provincial Department of Science and Technology 20210303003SFthe National Key R&D Program of China 2018YFC1315604
6 · The paper itself

Abstract

Streak artifacts in non-contrast computed tomography (NCCT) can obscure anatomical details and even confuse radiologic signs. Existing methods for artifact reduction have limitations: specialized training data and high annotation costs hinder the performance scalability, inadequate anatomical constraints struggle to preserve fine details, and limited generative stability along with suboptimal artifact reduction compromises diagnostic applicability. Leveraging 96,641 CT slices (763 series) from four different CT scanners (100-140 kilovolt peak (kVp), 55-167 tube current-time product (mAs), 0.5-10 mm thickness), we proposed a novel guided diffusion method using multi-level anatomical segmentations to optimize streak artifact reduction in chest NCCT scans. During training, the model integrates artifact-free CT slices with segmentation maps and anatomical regions of interest (ROIs) via channel-wise concatenation at each diffusion step. During inference, artifact-affected samples are fed into the trained model to generate artifact-free outputs with structural integrity. Statistical analysis revealed a significant (p < 0.05) difference in Signal-to-Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR) when comparing 47,032 artifact-affected samples to 49,609 artifact-free counterparts. Quantitative assessments demonstrated high consistency between generated outputs and reference standard artifact-free samples, with lung field SNR values of (26.67, standard deviation (SD) 2.01) vs. (26.11, SD 1.89) and lung-trachea CNR of (3.76, SD 0.77) vs. (3.78, SD 0.56) (both p > 0.05). Compared to four novel studies, our method achieved superior overall Peak Signal-to-Noise Ratio (PSNR) (36.952, SD 0.671), Structural Similarity Index (SSIM) (0.863, SD 0.013), and Dice Similarity Coefficient (DSC) (0.959, SD 0.031), with all p < 0.05. Moreover, ablation studies indicated that an appropriate segmentation guidance (Level-2) optimally balances anatomical structure constraints and artifact reduction efficiency, demonstrating superior performance in distinct organ or tissue regions compared to coarser and finer-grained guidance strategies. The proposed method has the potential to improve clinical analysis for chest NCCT by optimizing streak artifact reduction while enhancing medical image quality.

Indexed as

ArtifactsImage Processing, Computer-AssistedRadiography, ThoracicTomography, X-Ray ComputedAlgorithmsHumansSignal-To-Noise RatioDeep learningDiffusion modelsGuided diffusionMedical image segmentationStreak artifact reduction

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.