ArticleMedical & biological engineering & computing2026
A multi-level segmentation-guided diffusion model for streak artifact reduction in routine non-contrast chest CT.
Article in Medical & biological engineering & computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Streak artifacts in non-contrast computed tomography (NCCT) can obscure anatomical details and even confuse radiologic signs. Existing methods for artifact reduction have limitations: specialized training data and high annotation costs hinder the performance scalability, inadequate anatomical constraints struggle to preserve fine details, and limited generative stability along with suboptimal artifact reduction compromises diagnostic applicability. Leveraging 96,641 CT slices (763 series) from four different CT scanners (100-140 kilovolt peak (kVp), 55-167 tube current-time product (mAs), 0.5-10 mm thickness), we proposed a novel guided diffusion method using multi-level anatomical segmentations to optimize streak artifact reduction in chest NCCT scans. During training, the model integrates artifact-free CT slices with segmentation maps and anatomical regions of interest (ROIs) via channel-wise concatenation at each diffusion step. During inference, artifact-affected samples are fed into the trained model to generate artifact-free outputs with structural integrity. Statistical analysis revealed a significant (p < 0.05) difference in Signal-to-Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR) when comparing 47,032 artifact-affected samples to 49,609 artifact-free counterparts. Quantitative assessments demonstrated high consistency between generated outputs and reference standard artifact-free samples, with lung field SNR values of (26.67, standard deviation (SD) 2.01) vs. (26.11, SD 1.89) and lung-trachea CNR of (3.76, SD 0.77) vs. (3.78, SD 0.56) (both p > 0.05). Compared to four novel studies, our method achieved superior overall Peak Signal-to-Noise Ratio (PSNR) (36.952, SD 0.671), Structural Similarity Index (SSIM) (0.863, SD 0.013), and Dice Similarity Coefficient (DSC) (0.959, SD 0.031), with all p < 0.05. Moreover, ablation studies indicated that an appropriate segmentation guidance (Level-2) optimally balances anatomical structure constraints and artifact reduction efficiency, demonstrating superior performance in distinct organ or tissue regions compared to coarser and finer-grained guidance strategies. The proposed method has the potential to improve clinical analysis for chest NCCT by optimizing streak artifact reduction while enhancing medical image quality.