ArticleIEEE transactions on medical imaging2026
Axon Diameter Mapping From Myelin Water Diffusion MRI.
Article in IEEE transactions on medical imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Clinical Soma and Neurite Density Imaging (SANDI): Translational Microstructure Mapping on Clinical 3T MRI Scanners.Magnetic resonance in medicine · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Probing diffusion in myelin water using diffusion-weighted ${T} {_{{1}}}$ -/ ${T} {_{{2}}}$ -selective MRI acquisitions enables noninvasive measurement of myelinated axon diameter. Its application for in vivo measurements requires numerical verification through diffusion simulations. Here, we propose the theory of myelin water diffusion as measured with a diffusion MRI pulse sequence with wide gradient pulses using the Gaussian phase approximation. We establish its applicability to axonal diameter mapping via Monte Carlo simulations in either infinitely thin cylindrical surfaces or concentric cylindrical shells of finite thickness, mimicking the micro-geometry of myelin sheaths. The estimated diameters are shown to be weighted more toward outer than inner calibers. Simulation results evaluate the theory of myelin water diffusion and axon diameter estimation using spherical mean diffusion signals, demonstrating its applicability at signal-to-noise ratio above 20 on the Connectome 2.0 MRI scanner equipped with maximum gradient strength of 500 mT/m and slew rate of 600 T/m/s. Measuring restricted diffusion of myelin water in-between myelin sheaths using diffusion MRI allows one to measure myelinated axon diameters in vivo. The protocol can potentially be adapted for clinically available high-gradient performance scanners.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.