Evidence map›Paper›PMID 41685225›Full record

ArticleAdvances in radiation oncology2026

Myeloablative Total Body Irradiation With Volumetric Modulated Arc Therapy for Children-a Single Center Experience.

Hoong Hoong Ng, Munira Mohd Rejab, David Lee, Xin Yee Chiew, Syaza Ab Rahman, Ngie Min Ung, Zulaikha Jamalludin, Aik Hao Ng, Hany Ariffin, Nisha Shariff

Abstract read
In one paragraph

Article in Advances in radiation oncology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Hoong Hoong NgDepartment of Clinical Oncology, Universiti Malaya Medical Centre, Kuala Lumpur, Malaysia.
Munira Mohd RejabDepartment of Clinical Oncology, Universiti Malaya Medical Centre, Kuala Lumpur, Malaysia.
David LeeDepartment of Clinical Oncology, Universiti Malaya Medical Centre, Kuala Lumpur, Malaysia.
Xin Yee ChiewDepartment of Pediatrics, Universiti Malaya Medical Centre, Kuala Lumpur, Malaysia.
Syaza Ab RahmanDepartment of Pediatrics, Universiti Malaya Medical Centre, Kuala Lumpur, Malaysia.
Ngie Min UngMedical Physics Centre, Universiti Malaya Medical Centre, Kuala Lumpur, Malaysia.
Zulaikha JamalludinDepartment of Clinical Oncology, Universiti Malaya Medical Centre, Kuala Lumpur, Malaysia.
Aik Hao NgDepartment of Clinical Oncology, Universiti Malaya Medical Centre, Kuala Lumpur, Malaysia.
Hany AriffinDepartment of Pediatrics, Universiti Malaya Medical Centre, Kuala Lumpur, Malaysia.
Nisha ShariffDepartment of Clinical Oncology, Universiti Malaya Medical Centre, Kuala Lumpur, Malaysia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Total body irradiation (TBI) is a critical component of conditioning therapy prior to allogeneic hematopoietic stem cell transplantation in pediatric acute lymphoblastic leukemia. Our institution implemented volumetric modulated arc therapy-TBI (VMAT-TBI) in 2023, aiming to improve target conformity and organ-at-risk sparing using standard linear accelerators. This study describes our initial 2-year institutional experience with VMAT-TBI, focusing on treatment planning and delivery metrics, as well as early clinical outcomes and acute toxicities in pediatric patients. Methods and Materials: We conducted a review of 10 pediatric patients treated with VMAT-TBI at our institution from October 2023 to June 2025. All patients received myeloablative conditioning with 12 Gy in 6 fractions over 3 days, followed by intravenous etoposide preceding allogeneic hematopoietic stem cell transplantation. Data collected included treatment planning parameters, planning duration, delivery times, overall survival, relapse-free survival, and acute toxicities. Results: Treatment plans achieved robust target coverage ( Conclusions: Our early institutional experience demonstrates that VMAT-TBI is safe, feasible, and effective in pediatric patients, achieving excellent target coverage and acceptable acute toxicity profiles. These findings support the viability of implementing VMAT-TBI even in resource-constrained settings.

Identifiers

PMID41685225
PMCPMC12890799

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.