Evidence map›Paper›PMID 41685185›Full record

ArticleFrontiers in bioengineering and biotechnology2026

Finite element analysis of the influence of fragment size on biomechanical outcomes of various fixation techniques for posterolateral tibial plateau fractures.

Zhenghui Hu, Yanze Xia, Gaolong Shi, Chenying Wu, Liubing Li

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Zhenghui Hu *Department of Orthopedics Surgery, The Second Affiliated Hospital of Soochow University, Soochow, Jiangsu Province, China.
Yanze Xia *Department of Orthopedics Surgery, The Second Affiliated Hospital of Soochow University, Soochow, Jiangsu Province, China.
Gaolong ShiDepartment of Orthopedics Surgery, The Second Affiliated Hospital of Soochow University, Soochow, Jiangsu Province, China.
Chenying WuDepartment of Orthopedics Surgery, The Second Affiliated Hospital of Soochow University, Soochow, Jiangsu Province, China.
Liubing LiDepartment of Orthopedics Surgery, The Second Affiliated Hospital of Soochow University, Soochow, Jiangsu Province, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: This study aimed to compare the biomechanical stability of different-sized posterolateral tibial plateau fracture fragments under various internal fixation methods using three-dimensional finite element analysis (FEA) and to evaluate the influence of fragment size on displacement and stress distribution with L-shaped and posterior T-shaped plate fixation. Methods: Three-dimensional FEA models of posterolateral tibial plateau fractures were constructed based on computed tomography (CT) data of an adult tibia. Large and small fracture fragments were simulated, with fixation using an L-shaped plate (large fragment: dual-screw transverse arm fixation; small fragment: single-screw transverse arm fixation) or a posterior T-shaped tibial plate (large fragment: four-screw fixation; small fragment: three-screw fixation). Axial loads of 250 N, 500 N, and 750 N were applied to each model. Maximum displacement and maximum von Mises stress of the fixation constructs were recorded and compared under a 750 N load. Results: Under a 750 N axial load, FEA revealed: (1) L-shaped plate fixation group: the large-fragment model (dual-screw transverse arm) exhibited a maximum fixation displacement of 0.32 mm and a maximum von Mises stress of 349 MPa, whereas the small-fragment model (single-screw transverse arm) showed a maximum displacement of 0.37 mm and a maximum stress of 454 MPa. (2) Posterior T-shaped plate fixation group: the large-fragment model (four screws) demonstrated a maximum displacement of 0.29 mm and a maximum stress of 189 MPa, while the small-fragment model (three screws) had a maximum displacement of 0.32 mm and a maximum stress of 176 MPa. Overall displacement differences across groups were minimal, and the stress values of all fixation constructs remained below their yield strength, indicating no risk of failure. Conclusion: Finite element analysis indicates that fragment size significantly affects the biomechanical stability of internal fixation for posterolateral tibial plateau fractures. For smaller fragments, L-shaped plate fixation with a single-screw transverse arm results in significantly elevated fixation stress. In contrast, posterior T-shaped plate fixation maintains favorable stability and lower stress, even with fewer proximal screws. Thus, for smaller posterolateral tibial plateau fracture fragments, posterior T-shaped plate fixation may represent a biomechanically superior option.

Indexed as

finite element analysisFragment SizeL-shaped plateposterolateral tibial plateau fractureT-shaped plate

Identifiers

PMID41685185
PMCPMC12891237

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.