ArticleJournal of medical physics
Application and Optimization of Lee Filter for Segmentation of Benign Tumor in Breast Ultrasound Images.
Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Aims: In this study, we aimed to optimize the window size of Lee filter for speckle noise reduction in breast ultrasound images (BUSIs) by evaluating the segmentation performance of benign tumors using a U-Net model. Subjects and Methods: Benign tumor images were acquired with added speckle noise (intensity = 0.05) to obtain the noisy images. A Lee filter was applied to noisy images with window sizes of 3 × 3, 5 × 5, 7 × 7, and 9 × 9. To evaluate noise reduction and segmentation performance, noisy and filtered images were used as input images for the U-Net model. The segmentation performance according to various window sizes of the Lee filter was quantitatively evaluated using intersection over union (IoU), peak signal to noise ratio (PSNR), and universal quality image index (UQI). Results: As a result, a window size of 7 × 7 achieved the highest performance across all evaluation factors. In particular, when comparing the image with a 7 × 7 window size to the noisy image, the segmentation performance exhibited average improvements of approximately 19%, 5%, and 19% in IoU, PSNR, and UQI, respectively, with maximum improvements of approximately 27%, 7%, and 23%. Conclusions: This study demonstrated that applying the Lee filter with an optimized 7 × 7 window size improved speckle noise reduction and segmentation accuracy in BUSIs, supporting the applicability of deep learning-based tumor segmentation in clinical practice.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials