Evidence map›Paper›PMID 41684505›Full record

ArticleJournal of medical physics

Application and Optimization of Lee Filter for Segmentation of Benign Tumor in Breast Ultrasound Images.

Hajin Kim, Youngjin Lee

Abstract read
In one paragraph

Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Hajin KimDepartment of Health Science, General Graduate School of Gachon University, Incheon, Korea.
Youngjin LeeDepartment of Radiological Science, Gachon University, Incheon, Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aims: In this study, we aimed to optimize the window size of Lee filter for speckle noise reduction in breast ultrasound images (BUSIs) by evaluating the segmentation performance of benign tumors using a U-Net model. Subjects and Methods: Benign tumor images were acquired with added speckle noise (intensity = 0.05) to obtain the noisy images. A Lee filter was applied to noisy images with window sizes of 3 × 3, 5 × 5, 7 × 7, and 9 × 9. To evaluate noise reduction and segmentation performance, noisy and filtered images were used as input images for the U-Net model. The segmentation performance according to various window sizes of the Lee filter was quantitatively evaluated using intersection over union (IoU), peak signal to noise ratio (PSNR), and universal quality image index (UQI). Results: As a result, a window size of 7 × 7 achieved the highest performance across all evaluation factors. In particular, when comparing the image with a 7 × 7 window size to the noisy image, the segmentation performance exhibited average improvements of approximately 19%, 5%, and 19% in IoU, PSNR, and UQI, respectively, with maximum improvements of approximately 27%, 7%, and 23%. Conclusions: This study demonstrated that applying the Lee filter with an optimized 7 × 7 window size improved speckle noise reduction and segmentation accuracy in BUSIs, supporting the applicability of deep learning-based tumor segmentation in clinical practice.

Indexed as

Benign tumor segmentationbreast ultrasound imageLee filterquantitative evaluationspeckle noise reductionwindow size optimization

Identifiers

PMID41684505
PMCPMC12893366

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.