Evidence map›Paper›PMID 41684502›Full record

ArticleJournal of medical physics

Assessing Axis-specific Set-up Errors in Rectal Cancer Radiotherapy: A Prospective Cone-beam Computed Tomography-Based Study with Body Mass Index Correlation.

Ainain Yousuf Baba, Abid Ahmad, Obair Yousuf Baba, Misbah Shahid

Registry-linked trialAbstract read
In one paragraph

Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07676032 (The Impact of Body Composition on Setup Errors in Patients Undergoing Radiotherapy With Thermoplastic Mask Immobilization), which is not on this map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07676032 not yet recruitingnot on this map

The Impact of Body Composition on Setup Errors in Patients Undergoing Radiotherapy With Thermoplastic Mask Immobilization: A Single-Center Prospective Cohort Study

Typeobservational_patient_registrySponsorShijiazhuang People's HospitalRan2026 to 2027Enrolled150ConditionsMalignant Neoplasms
3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ainain Yousuf BabaDepartment of Physics, University of Kashmir, Srinagar, Jammu and Kashmir, India.
Abid AhmadDepartment of Pediatrics and Neonatology, Sher-I-Kashmir Institute of Medical Sciences, Srinagar, Jammu and Kashmir, India.
Obair Yousuf BabaDepartment of Otorhinolaryngology and Head and Neck Surgery, Acharya Shri Chander College of Medical Sciences and Hospital, Jammu, Jammu and Kashmir, India.
Misbah ShahidDepartment of Ophthalmology, Acharya Shri Chander College of Medical Sciences and Hospital, Jammu, Jammu and Kashmir, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The purpose of the study was to quantify set-up errors and derive optimal clinical target volume to Planning Target Volume (PTV) margins for rectal cancer patients undergoing radiotherapy, while also evaluating the influence of body mass index (BMI) on set-up accuracy. Materials and Methods: Data from 41 patients and 1102 daily cone-beam computed tomography (CBCT) scans were analyzed. For each patient and fraction, the mediolateral (X), craniocaudal (Y), and antero-posterior (Z) translational shifts were measured. Population systematic (Σ) and random (σ) errors were calculated from per-patient summary statistics (see Methods), and PTV margins were derived using the van Herk formula (margin = 2.5 Σ +0.7 σ). Results: The mean systematic set-up error was small: 0.04 mm (X), 0.57 mm (Y), and 0.13 mm (Z), reflecting high reproducibility of daily image-guided positioning. Using Σ and σ, the derived PTV margins were 7.4 mm (X), 9.1 mm (Y), and 9.7 mm (Z). A moderate positive correlation between BMI and the Z-axis set-up error was observed ( Conclusion: Nonuniform, axis-specific margins are essential to accommodate anatomical and physiological variability in rectal cancer radiotherapy. The use of daily CBCT significantly enhanced set-up precision. Findings align with ICRU 62/83 and QUANTEC recommendations and support individualized planning approaches, especially in diverse patient populations where BMI and pelvic anatomy may affect positioning accuracy.

Indexed as

Body mass index correlationplanning target volume-clinical target volume marginradiotherapyrandom errorrectal cancerssystematic error

Identifiers

PMID41684502
PMCPMC12893374

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.