Commissioning of Bilateral (Parallel Opposed) Extended Source-to-surface Distance Total Body Irradiation Technique and Its Long-term Stability.

Tharmarnadar Ganesh, Biplab Sarkar, Anusheel Munshi, Bidhu Kalyan Mohanti, S Venu Gopal, Gourav Gulia, Soumya Roy, Harpreet Kaur, Satheeshkumar Anbazhagan, Kanan Jassal and 5 more

Abstract read
In one paragraph

Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors.

Tharmarnadar GaneshDepartment of Radiation Oncology, Fortis Memorial Research Institute, Gurgaon, Haryana, India.
Biplab SarkarDepartment of Radiation Oncology, Fortis Memorial Research Institute, Gurgaon, Haryana, India.
Anusheel MunshiDepartment of Radiation Oncology, Fortis Memorial Research Institute, Gurgaon, Haryana, India.
Bidhu Kalyan MohantiDepartment of Radiation Oncology, Fortis Memorial Research Institute, Gurgaon, Haryana, India.
S Venu GopalDepartment of Radiation Oncology, Fortis Memorial Research Institute, Gurgaon, Haryana, India.
Gourav GuliaDepartment of Radiation Oncology, Fortis Memorial Research Institute, Gurgaon, Haryana, India.
Soumya RoyDepartment of Radiation Oncology, Fortis Memorial Research Institute, Gurgaon, Haryana, India.
Harpreet KaurDepartment of Radiation Oncology, Fortis Memorial Research Institute, Gurgaon, Haryana, India.
Satheeshkumar AnbazhaganDepartment of Radiation Oncology, Fortis Memorial Research Institute, Gurgaon, Haryana, India.
Kanan JassalDepartment of Radiation Oncology, Fortis Memorial Research Institute, Gurgaon, Haryana, India.
Sasikumar RathinamuthuDepartment of Radiation Oncology, Fortis Memorial Research Institute, Gurgaon, Haryana, India.
Upendra K GiriDepartment of Radiation Oncology, Fortis Memorial Research Institute, Gurgaon, Haryana, India.
Sandeep Singh DhilanDepartment of Radiation Oncology, Fortis Memorial Research Institute, Gurgaon, Haryana, India.
Vijendra KumarDepartment of Medical and Radiation Physics, National Institute of Science Education and Research, Bhubaneswar, Odisha, India.
Pallab SarkarDepartment of Physiology, City College, Kolkata, West Bengal, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aim: This article describes the commissioning of a total body irradiation (TBI) technique using bilateral-parallel-opposed fields at extended source-to-surface distance (SSD). Material: The measurements are based on the actual patient treatment geometry, which requires the patient to be placed inside a Perspex box. The gaps between the patient and the walls of the Perspex box were filled with rice bags to achieve full scattering conditions. The TBI box's lateral separation can be adjusted to 42 cm, 52 cm, or 62 cm by inserting the removable side walls to either of the three pairs of slots. A Farmer chamber, inserted inside a water-equivalent plastic slab phantom placed under full scattering conditions, was used for depth dose and profile measurements. The extended SSD was 333.5 cm, and the available field size was 132 cm × 132 cm. For output measurement, dose-to-water calibration factors for 6 MV and 15 MV energies were derived for the extended SSD. Bilateral-opposed fields were measured at three different separations to calculate lateral tissue effects. Result: For the 6 MV and 15 MV beams at a 42 cm separation, the midline-to-surface dose ratios were 1:1.17 and 1:1.08, respectively. As the separation increased, this ratio increased faster for the 6 MV beam and slower for the 15 MV beam. For the end-to-end quality assurance test (monitor unit to dose verification), the noted deviations were - 2.16% for the 6 MV beam and - 1.27% for the 15 MV beam. Conclusion: This article presents the detailed commissioning and long-term stability of the extended SSD TBI technique.

Indexed as

Bilateralextended source-to-surface distancetotal body irradiation

Identifiers

PMID41684496
PMCPMC12893365

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.