Evidence map›Paper›PMID 41684491›Full record

ArticleJournal of medical physics

Dosimetric Validation of Treatment Plan Interchangeability between Factory Beam-matched Varian TrueBeam and Clinac Linear Accelerators for Volumetric Modulated Arc Therapy and IMRT Delivery.

Mukesh Kumar Zope, Deepali Patil, Seema Devi, Devraj Singh

Abstract read
In one paragraph

Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Mukesh Kumar ZopeDepartment of Medical Physics, State Cancer Institute, Indira Gandhi Institute of Medical Sciences, Patna, Bihar, India.
Deepali PatilDepartment of Medical Physics, State Cancer Institute, Indira Gandhi Institute of Medical Sciences, Patna, Bihar, India.
Seema DeviDepartment of Radiation Oncology, State Cancer Institute, Indira Gandhi Institute of Medical Sciences, Patna, Bihar, India.
Devraj SinghDepartment of Physics, Veer Bahadur Singh Purvanchal University, Jaunpur, Uttar Pradesh, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The purpose of this study was to assess the dosimetric consistency and clinical interchangeability of treatment plans between factory beam-matched Varian TrueBeam SVC and Clinac iX linear accelerators across various anatomical locations. Materials and Methods: Eighty clinical plans were analyzed, including 40 intensity modulated radiotherapy (IMRT) plans (20 for cervix and 20 for head and neck) and 40 volumetric modulated arc therapy (VMAT) plans (20 for breast and 20 for urinary bladder). Both linacs were independently commissioned per AAPM-106 protocols. Plans were recalculated on the alternate machine and compared statistically. Patient-specific QA was performed using ArcCHECK with 3%/2 mm gamma criteria. Transferable fractions were estimated using ICRU-50 (±5%) and AAPM TG-40 (±2%) guidelines to determine fractions safely deliverable without re-planning. Results: Beam commissioning showed excellent agreement within ±1% for all dosimetric parameters. Head and neck IMRT had minimal differences (D95%: -0.26%, Conclusions: Linear accelerators that are beam-matched in factories provide safe interchangeability of treatment plans for the majority of clinical scenarios, with VMAT showing improved consistency over IMRT due to continuous arc delivery averaging out minor machine-specific variations in multileaf collimator positioning and dose rate.

Indexed as

Beam matchingdosimetric comparisonpatient-specific QAtreatment planning

Identifiers

PMID41684491
PMCPMC12893353

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.