Evidence map›Paper›PMID 41682595›Full record

ArticleSensors (Basel, Switzerland)2026

Open-Set Recognition of Human Activities from Head-Mounted Inertial Sensor.

Angela Cortese, Sarah Solbiati, Alice Scandelli, Andrea Giudici, Niccolò Antonello, Diana Trojaniello, Giacomo Boracchi, Enrico Gianluca Caiani

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Angela CorteseDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy.ORCID 0009-0009-2345-7699
Sarah SolbiatiDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy.ORCID 0000-0002-0053-4198
Alice ScandelliDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy.ORCID 0009-0006-4198-6680
Andrea GiudiciDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy.
Niccolò AntonelloEssilorLuxottica Smart Eyewear Lab, EssilorLuxottica, Piazzale Luigi Cadorna 3, 20123 Milan, Italy.ORCID 0000-0002-0803-5385
Diana TrojanielloEssilorLuxottica Smart Eyewear Lab, EssilorLuxottica, Piazzale Luigi Cadorna 3, 20123 Milan, Italy.
Giacomo BoracchiDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy.
Enrico Gianluca CaianiDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy.ORCID 0000-0002-1770-6486

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Human activity recognition (HAR) based on inertial measurement units (IMUs) embedded in wearable devices has gained increasing relevance in healthcare, wellness, and fitness monitoring. However, most existing classification methods assume a closed-set setting, where all activity classes need to be defined during training, which limits their applicability in real-world environments where unseen or unexpected activities are present. To overcome this limitation, we adopt an open-set recognition (OSR) framework that requires minimal changes to the HAR classifiers traditionally employed for this purpose. We also provide an extensive empirical evaluation based on a leave-one-activity-out validation protocol applied to two datasets with IMU signals acquired from smart eyewear: a proprietary dataset and the publicly available UCA-EHAR dataset. A lightweight one-dimensional convolutional neural network was trained to classify six-axis IMU data across common activities. We assess open-set HAR performance using several methods requiring limited computational overhead and operating in the logit space, including maximum logit, Gaussian Mixture Models, Kernel Density Estimation, OpenMax, and Nearest Neighbor Distance Ratio. Robust identification of unknown activities was achieved, with area under the ROC curve > 0.8. These findings highlight the potential of low-complexity open-set approaches for real-time HAR on resource-constrained wearable platforms, supporting the development of adaptive and reliable sensor-based recognition systems for real-world use.

Indexed as

HeadHuman ActivitiesWearable Electronic DevicesAlgorithmsClassification AlgorithmsConvolutional Neural NetworksHumansNeural Networks, Computerhuman activity recognitioninertial measurement unitsopen-set recognitionsmart eyewearwearable sensors