Evidence map›Paper›PMID 41682443›Full record

ArticleSensors (Basel, Switzerland)2026

A Vision-Based Algorithm for Assessing Head and Hand Tremor: Development and Validation Against IMU Sensors.

Slavka Netukova, Jan Tesař, Tereza Hubená, Petr Hollý, Evžen Růžička, Radim Krupička

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Slavka NetukovaDepartment of Biomedical Informatics, Faculty of Biomedical Engineering, Czech Technical University in Prague, 272 01 Kladno, Czech Republic.ORCID 0000-0002-0383-8787
Jan TesařDepartment of Biomedical Informatics, Faculty of Biomedical Engineering, Czech Technical University in Prague, 272 01 Kladno, Czech Republic.
Tereza HubenáDepartment of Biomedical Informatics, Faculty of Biomedical Engineering, Czech Technical University in Prague, 272 01 Kladno, Czech Republic.ORCID 0000-0003-3468-9822
Petr HollýDepartment of Neurology and Centre of Clinical Neuroscience, First Faculty of Medicine, Charles University and General University Hospital, 128 21 Prague, Czech Republic.ORCID 0000-0002-5242-8725
Evžen RůžičkaDepartment of Neurology and Centre of Clinical Neuroscience, First Faculty of Medicine, Charles University and General University Hospital, 128 21 Prague, Czech Republic.ORCID 0000-0002-4893-9661
Radim KrupičkaDepartment of Biomedical Informatics, Faculty of Biomedical Engineering, Czech Technical University in Prague, 272 01 Kladno, Czech Republic.ORCID 0000-0002-0280-215X

Funding

Czech Health Research Council NW26-04-00151
6 · The paper itself

Abstract

Tremor is the most prevalent human movement disorder, characterized by rhythmic oscillations of a body part. Accurate tremor assessment is essential for diagnosis, monitoring, and treatment evaluation. Traditional methods rely on accelerometry-based measurements, requiring direct sensor attachment, which may be impractical in some settings. We developed a novel algorithm for detecting tremors from video recordings based on the motion of the center of mass and implemented it in the open-source software TremAn3. Motion data were extracted from 2D video recordings of both hands and the head, and spectral analysis was then performed to quantify the tremor by calculating peak tremor power and peak power frequency. A total of 30 videos were recorded from 30 participants with essential or dystonic tremors. Simultaneously, acceleration signals were collected using inertial measurement units (IMUs) placed on the backs of the hands and forehead as a gold-standard reference. Agreement between video- and IMU-derived metrics was assessed using intraclass correlation coefficients (ICCs) and mean absolute error (MAE). For PP, video-based estimates showed moderate-to-good agreement (ICC: 0.70 left hand, 0.77 right hand, 0.80 head) with MAE of 8.12-10.80 dB. For PPF, agreement was moderate for the hands (ICC: 0.60 left, 0.67 right; MAE: 0.54-0.76 Hz) but poor for head PPF (ICC: 0.08; MAE: 2.06 Hz). Our results indicate that video analysis can serve as a viable alternative to traditional accelerometry for tremor quantification. This contactless method holds significant potential for telemedicine and research applications.

Indexed as

AlgorithmsHandHeadTremorAccelerometryAgedFemaleHumansMaleMiddle AgedVideo Recordingcameracomputer visioncontactless measurementspectral analysistremorvideo

Identifiers

PMID41682443
PMCPMC12899472

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.