ArticleCommunications engineering2026
A gallium arsenide hybrid-pixel counting detector for 100 keV cryo-electron microscopy.
Article in Communications engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The recent interest in 100 keV cryo-electron microscopy has created a demand for specialized detectors that maximize information per unit dose while remaining cost-effective. We present a hybrid-pixel electron counting detector system tailored for cryo-electron microscopy applications using 100 keV electron energy. The demonstrator uses a 500 μm-thick, chromium-compensated gallium arsenide (high-Z) sensor with a 36 μm pixel pitch arranged in a seamless 1266 × 1057 matrix. Its low-noise front-end electronics achieve a threshold energy as low as 2.5 keV and include an in-pixel hit digitization mechanism. The matrix is read out at a speed of 7.2 kfps and has a counter depth of 1 bit, allowing for an incoming rate of 28 e/s/pix at 5% coincidence loss. The imaging performance is evaluated in standard counting and super-resolution acquisition modes. Thanks to a custom-developed super-resolution algorithm, the detective quantum efficiency at zero-frequency amounts to 0.96 and at the physical Nyquist frequency to 0.56, resulting in an effective pixel size of 27.5 μm. Experimental data are complemented and critically compared with Monte Carlo simulations and analytical models.