Evidence map›Paper›PMID 41678122›Full record

ArticleHepatology international2026

Coaxial stent TIPS with 5 to 8 mm controlled expansion improving overall prognosis in cirrhotic patients: a prospective cohort study with target trial emulation.

Li Ma, Jingqin Ma, Jiaze Yu, Yaozu Liu, Yongjie Zhou, Minjie Yang, Zhiping Yan, Jianjun Luo, Wen Zhang

Abstract read
PubMed Publisher
In one paragraph

Article in Hepatology international, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Li Ma *Department of Interventional Radiology, Zhongshan Hospital, Fudan University, No. 180 Fenglin Road, Shanghai, 200032, China.
Jingqin Ma *Department of Interventional Radiology, Zhongshan Hospital, Fudan University, No. 180 Fenglin Road, Shanghai, 200032, China.
Jiaze Yu *Department of Interventional Radiology, Zhongshan Hospital, Fudan University, No. 180 Fenglin Road, Shanghai, 200032, China.
Yaozu LiuDepartment of Interventional Radiology, Zhongshan Hospital, Fudan University, No. 180 Fenglin Road, Shanghai, 200032, China.
Yongjie ZhouDepartment of Interventional Radiology, Zhongshan Hospital, Fudan University, No. 180 Fenglin Road, Shanghai, 200032, China.
Minjie YangDepartment of Interventional Radiology, Zhongshan Hospital, Fudan University, No. 180 Fenglin Road, Shanghai, 200032, China.
Zhiping YanDepartment of Interventional Radiology, Zhongshan Hospital, Fudan University, No. 180 Fenglin Road, Shanghai, 200032, China. yan.zhiping@zs-hospital.sh.cn.
Jianjun LuoDepartment of Interventional Radiology, Zhongshan Hospital, Fudan University, No. 180 Fenglin Road, Shanghai, 200032, China. luo.jianjun@zs-hospital.sh.cn.ORCID http://orcid.org/0000-0003-4942-0439
Wen ZhangDepartment of Interventional Radiology, Zhongshan Hospital, Fudan University, No. 180 Fenglin Road, Shanghai, 200032, China. zhang.wen2@zs-hospital.sh.cn.

Funding

National Clinical Key Specialty Construction Project of China YWP2024-001National Natural Science Foundation of China 82302323
6 · The paper itself

Abstract

BACKGROUND AND

aimCirrhotic patients receiving trans-jugular intrahepatic portosystemic shunt (TIPS) for preventing re-bleeding may benefit from a shunt diameter of ≤ 8 mm. This study aimed to emulate a target trial comparing decompensation-free survival in patients receiving coaxial stent versus fully- or under-dilated 8 mm TIPS for preventing variceal re-bleeding. APPROACH: Participants were recruited from a single-center, prospective, non-randomized cohort after excluding patients impossible to be assigned to the coaxial stent group. The coaxial stent consisted of a pre-implanted 5-/6 mm balloon-expandable stent with an internal 8 mm Viatorr stent. Causal inference framework was designed based on a directed acyclic graph, incorporating inverse probability weighting (IPW), doubly robust estimation by augmented IPW, mediation analysis, and E value analysis.

results200 patients entered into target trial emulation, with 47 (23.5%), 101 (50.5%), and 52 (26.0%) in coaxial stent, under-dilated, and fully dilated groups. Coaxial stent feasibility was demonstrated by portacaval pressure gradient adjustability (33 pairs before/after dilation: 22.8 ± 3.0 to 17.9 ± 3.1 mmHg, p < 0.001) and stability (76 pairs without intervention: 17.7 ± 4.2 to 18.5 ± 4.5 mmHg, p = 0.035, r = 0.712, ICC = 0.710). Crude (IPW-weighted) 1-year decompensation-free survival incidences were 57.7% (52.6%), 60.1% (60.0%), and 76.6% (78.9%) for fully dilated, under-dilated, and coaxial stent groups, with doubly robust analysis revealing improved prognosis in coaxial stent versus fully dilated (HR 0.54 [0.25-0.93], p = 0.026, E value = 3.108, direct effect 66.3%) and under-dilated (HR 0.63 [0.34-1.05], p = 0.070, E value = 2.553, direct effect 60.7%) groups. Coaxial stent group demonstrated significantly reduced hepatic encephalopathy risk compared with other groups (p = 0.045/0.026), while other outcomes were comparable.

conclusionsThe coaxial stent TIPS strategy could effectively achieve controlled expansion of 5-8 mm and may improve overall prognosis in cirrhotic patients with previous variceal bleeding.

Indexed as

Esophageal and Gastric VaricesGastrointestinal HemorrhageLiver CirrhosisPortasystemic Shunt, Transjugular IntrahepaticStentsAgedFemaleHumansMaleMiddle AgedPrognosisProspective StudiesTreatment OutcomeCausal inferenceControlled expansionHepatic decompensationPortal hypertensionSmall diameter

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.