Evidence map›Paper›PMID 41677862›Full record

ArticlePediatric cardiology2026

Dual Chamber Aveir Retrievable Leadless Pacemaker Implant in a Patient with a Senning Baffle and Subcutaneous ICD.

Charles Bingham, Daniel Cortez

Abstract read
PubMed Publisher
In one paragraph

Article in Pediatric cardiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Charles BinghamDavidson College, Davidson, NC, USA.
Daniel CortezAdult Congenital and Pediatric Cardiology, University of California at Davis Medical Center, 77 Cadilac Drive, Sacramento, CA, 95825, USA. dancortez@ucdavis.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Patients with dextro-transposition (D-TGA) of the great arteries and Senning or Mustard baffles have risk of sinus node dysfunction as well as ventricular arrhythmias. We demonstrate the implantation of a dual-chamber leadless pacemaker in a patient with a Senning baffle and symptomatic bradycardia, in the setting of a primary prevention subcutaneous internal cardioverter defibrillator (SQICD). A retrospective review of a case of dual chamber leadless pacemaker (Aveir DR) implant was performed including atrial baffle and left ventricular septal implant. A 41-year-old female with history of D-TGA and prior defibrillator, post-lead extraction and SQICD placement, after lead malfunction, presented with symptomatic bradycardia. She underwent a dual-chamber leadless pacemaker implant under echocardiographic guidance without complication. At 6-month follow-up, the atrial and ventricular thresholds were 0.5 V@0.2ms and 0.75 V@0.2ms, with impedances of 350 ohms, and 730 ohms, respectively, with an R-wave of 17.3milliVolts. With 99% atrial pacing, and 15% ventricular pacing, the predicted longevity was 13.0 and 18.3 years for atrial and ventricular devices, respectively. No oversensing was noted on the subcutaneous ICD. The patient noted improved activity tolerance and no further presyncope. Successful implantation of a dual-chamber leadless pacemaker can be achieved in the LV septum of a patient with a Senning baffle and previously installed SICD.

Indexed as

Congenital heart diseaseDual chamberPacemaker

Identifiers

PMID41677862

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.