ArticleAME case reports2026
Assessment of atrial septal defect size during systole and diastole using 4D CT: a case series.
Article in AME case reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Atrial septal defect assessment: challenges of 4D cardiac computed tomography.AME case reports · 2026Article
Corrections and comments
- Commented on by
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: The size of atrial septal defects (ASDs) is typically measured using echocardiography. In contrast, computed tomography (CT) images offer superior spatial resolution, and four-dimensional (4D) CT enables visualization of the defect hole during various cardiac phases. In this study, we compared the results of 4D CT measurements of defect sizes during atrial systole (As) and atrial diastole (Ad) in 7 of 18 cases of robot-assisted ASD closure (Robotic ASD closure) with measurements obtained by other methods. Case Description: Robotic ASD closure was performed in 18 patients between December 2019 and April 2025. Surgery was performed under general anesthesia, with a venous line from the right internal jugular vein and right femoral vein, and an arterial line on the right femoral artery to establish extracorporeal circulation. The procedure was conducted using the DaVinci Xi Conclusions: Using 4D CT, it was possible to determine the morphology and area of ASD defects in As/Ad before surgery. This is useful for selecting surgical procedures and determining patch size and may contribute to reducing cardiac arrest and surgical time. To prove that 4D CT can accurately predict the size and morphology of the defects in As/Ad, further accumulation of cases and analyses are required.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.