Abstract read
In one paragraph

Article in Frontiers in robotics and AI, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Seyed MohammadReza SajadiDepartment of Informatics, University of Oslo, Oslo, Norway.
Abbas TariverdiDepartment of Physics, University of Oslo, Oslo, Norway.
Henrik BrunThe Intervention Center, Oslo University Hospital, Oslo, Norway.
Ole Jakob ElleDepartment of Informatics, University of Oslo, Oslo, Norway.
Kim MathiassenDepartment of Technology Systems, University of Oslo, Oslo, Norway.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: This paper presents a robotic transesophageal echocardiography (TEE) system that replicates all essential degrees of freedom available in manual TEE procedures. The developed robotic system advances dual-subsystem architectures through enhanced mechanical design and deep learning-based kinematic modeling. Methods: Building upon previous designs that manipulate the TEE probe from both handle and gastroscope tube, our system integrates with a teleoperated UR5 manipulator to accommodate both supine and left lateral decubitus patient positions, addressing the full spectrum of clinical TEE procedures. The system features 6 DOF at the probe handle and 2 DOF at the gastroscope tube. Together, these create optimal gastroscope tube geometry, minimizing cable tension asymmetry and friction-induced nonlinearities inherent in cable-driven mechanisms. The primary contribution is a data-driven kinematic model using recurrent neural networks with LSTM units that overcomes fundamental limitations of analytical approaches for continuum manipulators. Trained on 42,000 synchronized pose-command pairs collected across three gastroscope tube configurations (0°, 45°, 90° bends), the model effectively captures dead zones, hysteresis, and coupling effects between steering mechanisms. Results: Experimental validation demonstrates strong position tracking across all three gastroscope tube configurations. The model achieves RMSE of 1.267 mm for the 0° configuration, 1.209 mm for the 45° configuration, and 1.194 mm for the 90° configuration. Mean orientation errors are 7.064° at 0°, 8.503° at 45°, and 4.947° at the clinically critical 90° configuration. The model exhibits coordinate frame independence with only 0.06 mm RMSE difference between original and rotated datasets. This confirms true kinematic learning rather than coordinate-specific patterns. With 1.8 ms inference time, the system achieves real-time performance essential for clinical deployment. Discussion: This integration of robotic system design with deep learning establishes a foundation for semi-autonomous TEE systems. The developed system can support both diagnostic TEE examinations and TEE-guided structural heart interventions.

Indexed as

cable-driven mechanismcontinuum mechanismdeep learning kinematic modelingLSTMrobotic-assisted echocardiographyrobotic transesophageal echocardiographysynchronized robotic subsystems

Identifiers

PMID41675306
PMCPMC12887703

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.