ArticleResuscitation plus2026
A novel algorithm to determine ventilation parameters during cardiopulmonary resuscitation using pneumotachography waveform data.
Article in Resuscitation plus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: A major barrier to the analysis of ventilation waveform data collected during CPR is the presence of artefacts caused by chest compressions. This study describes the development and evaluation of an algorithm to extract parameters regarding ventilation volume, pressure, and frequency from pneumotachography waveform data collected during ongoing simulated CPR. Method: Ventilation waveform data was collected from a pneumotachograph connected to the respiratory circuit of a ventilator and a test lung. Both regular ventilation and ventilation during simulated CPR were used to develop the algorithm. A grid search was employed to optimize the algorithm parameters compared to the ventilator settings. The parameters were then manually tuned using clinical data from ventilation during CPR. The performance of the algorithm was described in terms of the median error vs. the known ventilator settings in the simulated data. Results: Compared to the ventilator settings, the largest systematic errors of the algorithm was an overestimation of peak pressures during asynchronous CPR (median error of 3 (IQR 0.3-5.8) cmH Conclusion: In an experimental setting, the developed algorithm provides a novel solution to measure ventilation parameters during ongoing chest compressions. The algorithm is freely available under an open-source licence for use and further development. Further studies will be needed to validate the algorithm.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.