Evidence map›Paper›PMID 41674238›Full record

ArticleJournal of separation science2026

A Chromatographic Approach for Simultaneous Quantification of Multiple Anticoagulants in Human Plasma Samples.

Federica Guidetti, Sara R Fernandes, Luisa Barreiros, Marcela A Segundo

Abstract read
In one paragraph

Article in Journal of separation science, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Federica GuidettiLAQV, REQUIMTE, Department of Chemical Sciences, Faculty of Pharmacy, University of Porto, Porto, Portugal.
Sara R FernandesLAQV, REQUIMTE, Department of Chemical Sciences, Faculty of Pharmacy, University of Porto, Porto, Portugal.
Luisa BarreirosLAQV, REQUIMTE, Department of Chemical Sciences, Faculty of Pharmacy, University of Porto, Porto, Portugal.
Marcela A SegundoLAQV, REQUIMTE, Department of Chemical Sciences, Faculty of Pharmacy, University of Porto, Porto, Portugal.

Funding

European Social Fund (ESF)FCT/MECI, Fundação para a Ciência e a TecnologiaFCT-Tenure - 1a EdiçãoLaboratório Associado para a Química Verde-Tecnologias e Processos LimposMinistério da Educação, Ciência e InovaçãoNorte 2020 COVID/BD/152406/2022Norte 2020 SFRH/BD/130948/2017
6 · The paper itself

Abstract

Anticoagulants are essential drugs for preventing and treating thromboembolic conditions by inhibiting blood clot formation. Warfarin, a vitamin K antagonist, is among the most prescribed agents but presents limitations, including a narrow therapeutic window and a high risk of adverse events, requiring strict monitoring to ensure both safety and therapeutic efficacy. In contrast, direct oral anticoagulants such as dabigatran, rivaroxaban, and apixaban offer improved safety profiles and generally do not require routine monitoring. Nevertheless, monitoring is required in special clinical situations, including emergencies, renal dysfunction, or for high-risk patients. In this context, the present study aimed to develop an HPLC method with UV/Vis detection for the simultaneous quantification of four anticoagulant agents (warfarin, dabigatran, rivaroxaban, and apixaban) in human plasma. Efficient separation of the four target analytes involved the evaluation of several parameters, including column type (Kinetex core-shell C18, Chromolith RP-18e, and Chromolith Phenyl), elution conditions, and injection volume (10-50 µL). The best separation was achieved within 12 min using a monolithic phenyl column and gradient elution, at a flow rate of 2 mL/min. The method was validated and has shown to be selective, linear in the range of 0.50-5.0 µg/mL for dabigatran and warfarin and 0.25-5.0 µg/mL for rivaroxaban and apixaban, accurate (85.7%-115.0%), and precise (CV ≤ 9.4%) for both intra- and inter-day assays. LOD and LOQ in plasma were ≤ 0.2 and ≤ 0.5 µg/mL, respectively. Stability testing demonstrated that all analytes remained stable at room temperature for 24 h, with only dabigatran showing reduced stability after three freeze-thaw cycles. The proposed method enabled rapid and simultaneous quantification of four clinically relevant anticoagulants in plasma samples.

Indexed as

AnticoagulantsWarfarinChromatography, High Pressure LiquidDabigatranHumansPyrazolesPyridonesRivaroxabanAnticoagulantsapixabanDabigatranPyrazolesPyridonesRivaroxabanWarfarinbiomatricesdirect oral anticoagulantsliquid chromatographytherapeutic drug monitoringvitamin K antagonist

Identifiers

PMID41674238
PMCPMC12895136

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.