Optimal elevation distance of the X-ray focus in vertical dual-exposure panoramic radiography for mitigating ghost images of cervical vertebrae in the upper incisor region.

Shoichi Asakura, Tomoyo Nomura, Ayuko Moriyama, Mutsumi Kishi, Yoshinori Arai, Kunihito Matsumoto

Abstract read
PubMed Publisher
In one paragraph

Article in Oral radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Shoichi AsakuraDepartment of Oral and Maxillofacial Radiology, Nihon University School of Dentistry, 1-8-13, Kanda-surugadai, Chiyoda-ku, Tokyo, 101-8310, Japan.
Tomoyo NomuraDepartment of Oral and Maxillofacial Radiology, Nihon University School of Dentistry, 1-8-13, Kanda-surugadai, Chiyoda-ku, Tokyo, 101-8310, Japan.
Ayuko MoriyamaDepartment of Oral and Maxillofacial Radiology, Nihon University School of Dentistry, 1-8-13, Kanda-surugadai, Chiyoda-ku, Tokyo, 101-8310, Japan.ORCID http://orcid.org/0009-0008-5193-0095
Mutsumi KishiDepartment of Oral and Maxillofacial Radiology, Nihon University School of Dentistry, 1-8-13, Kanda-surugadai, Chiyoda-ku, Tokyo, 101-8310, Japan.
Yoshinori AraiDepartment of Oral and Maxillofacial Radiology, Nihon University School of Dentistry, 1-8-13, Kanda-surugadai, Chiyoda-ku, Tokyo, 101-8310, Japan.ORCID http://orcid.org/0000-0002-6887-9088
Kunihito MatsumotoDepartment of Oral and Maxillofacial Radiology, Nihon University School of Dentistry, 1-8-13, Kanda-surugadai, Chiyoda-ku, Tokyo, 101-8310, Japan. matsumoto.kunihito@nihon-u.ac.jp.ORCID http://orcid.org/0000-0002-4045-976X

Funding

Japan Society for the Promotion of Science Grant-in-Aid for Scientific Research JP22K10133
6 · The paper itself

Abstract

objectivesPanoramic radiography (PR) often produces ghost images from cervical vertebrae (CVe) in the upper incisor region. Vertical dual-exposure panoramic radiography (VDPR) reduces these artifacts by merging two scans at different X-ray focus heights, but excessive elevation introduces incisor distortion. This study aimed to determine the optimal elevation distance that minimizes ghost images while limiting distortion.

methodsThree experiments were performed. (1) A theoretical model calculated the minimum elevation required to displace CV ghost images beyond their vertical width using cone-beam computed tomography (CBCT)-derived measurements of a cranial phantom. (2) Ghost images of CVe were simulated with CBCT data, with merged-CV images created as if the X-ray focus had been raised from 0 to 20 mm in 5-mm increments. Ghost image intensity was quantified by spatial bootstrapping of pixel variability. (3) Phantom experiments were performed with identical increments, and merged VDPR images were analyzed. Image quality was assessed using the standard deviation of brightness within defined regions of interest.

results(1) Theoretical analysis indicated an optimal elevation of 10 mm. (2) Simulation results confirmed that merged-CV image combining 0 mm and 10 mm produced the greatest reduction in ghost image intensity compared with other condition. (3) Phantom experiments demonstrated significant reduction at 5, 10, and 15 mm, with 10 mm providing the most consistent improvement. Elevations ≥ 15 mm introduced incisor distortion.

conclusionsVDPR with an X-ray focus elevation of 10 mm effectively mitigates CV ghost images in the upper incisor region while minimizing distortion, representing the optimal setting for clinical application.

Indexed as

ArtifactsCervical VertebraeIncisorRadiography, PanoramicCone-Beam Computed TomographyHumansPhantoms, ImagingCervical vertebraeGhost imageImage distortionPanoramic radiographyVertical dual-exposure

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.