Evidence map›Paper›PMID 41673176›Full record

ArticleJournal of robotic surgery2026

Comparison of the da Vinci Xi and hinotori surgical robotic systems using a training model: an ex vivo study.

Hiraku Yamamoto, Shimpei Yamashita, Hisanobu Tosuji, Nobuyuki Mashima, Ryusuke Deguchi, Yuya Iwahashi, Hiroki Kawabata, Satoshi Muraoka, Takahito Wakamiya, Isao Hara and 1 more

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Journal of robotic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Hiraku Yamamoto *Department of Urology, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan.
Shimpei Yamashita *Department of Urology, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan. keito608@wakayama-med.ac.jp.ORCID http://orcid.org/0000-0001-7402-6164
Hisanobu TosujiDepartment of Urology, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan.
Nobuyuki MashimaDepartment of Urology, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan.
Ryusuke DeguchiDepartment of Urology, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan.
Yuya IwahashiDepartment of Urology, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan.
Hiroki KawabataDepartment of Urology, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan.
Satoshi MuraokaDepartment of Urology, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan.
Takahito WakamiyaDepartment of Urology, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan.
Isao HaraDepartment of Urology, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan.
Yasuo KohjimotoDepartment of Urology, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Robotic-assisted surgery is widely adopted in urology, but there is little comparative data between established and newly introduced platforms. We used an ex vivo training model to compare task performance and subjective workload between the widely-established da Vinci Xi system and the hinotori system, which was developed in Japan. In this prospective crossover study, 16 urologists performed three standardized tasks (camera manipulation and grasping, cutting, and suturing with knot tying) under three robotic conditions: using da Vinci Xi with finger clutch, using da Vinci Xi without finger clutch, and using hinotori. Task completion time was recorded for each trial, and subjective workload was assessed after every task using the weighted NASA Task Load Index (NASA-TLX). Median task completion times tended to be longer with hinotori than with either of the da Vinci Xi conditions, although no significant differences were observed between the three systems for any of the tasks. In contrast, weighted NASA-TLX scores were significantly higher with hinotori than with the da Vinci Xi with finger clutch for the camera/grasping and suturing tasks, whereas no significant differences were detected between hinotori and the da Vinci Xi without finger clutch. The hinotori system demonstrated task performance that was comparable to that by the da Vinci Xi platform, while subjective workload was higher relative to the da Vinci Xi when the finger clutch function was used. Our results suggest that surgeon workload during robotic surgery may be strongly influenced by console-specific ergonomic features, particularly the presence or absence of a finger clutch function.

Indexed as

Robotic Surgical ProceduresUrologic Surgical ProceduresCross-Over StudiesHumansProspective StudiesTask Performance and AnalysisWorkloadda vinciHinotoriRobotic surgerySurgical training modelTask workload

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.