Evidence map›Paper›PMID 41673173›Full record

ArticleSkeletal radiology2026

Acetabular cup anteversion measurement in total hip arthroplasty: reliability of metal artifact reduction MRI compared with CT.

Frederik Abel, Patrick O Zingg, Reto Sutter, Florian Schmaranzer

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Skeletal radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Frederik AbelDepartment of Radiology, Faculty of Medicine, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland. frederik.abel@balgrist.ch.ORCID http://orcid.org/0000-0001-8988-6917
Patrick O ZinggDepartment of Orthopedic Surgery, Faculty of Medicine, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland.
Reto SutterDepartment of Radiology, Faculty of Medicine, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland.
Florian SchmaranzerDepartment of Radiology, Faculty of Medicine, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThe acetabular cup version in patients with total hip arthroplasty (THA) is a key parameter influencing hip stability and functional outcomes. Although CT remains the reference standard for assessing cup orientation, MRI with metal artifact reduction techniques is increasingly used for evaluating postoperative pain. This study compared MRI- and CT-based measurements of acetabular cup version regarding agreement, reproducibility, and reliability. MATERIAL AND

methodsPatients who underwent THA between 2015 and 2025 with postoperative CT and MRI were retrospectively analyzed. MRI was performed using optimized metal artifact reduction sequences. Acetabular cup version was measured on axial high-bandwidth T1-weighted turbo spin-echo sequences and on corresponding CT scans by two musculoskeletal radiologists. Inter- and intra-reader, as well as inter-modality agreement, were assessed using intraclass correlation coefficients (ICC). Bland-Altman plots evaluated systematic bias.

resultsThirty patients were included (mean age, 64.1 years; 14 women). Mean acetabular version was 31.2° (standard deviation (SD), 9.4-10.3) for CT and 30.1-30.2° (SD, 8.9-9.3) for MRI for both readers. Inter-reader agreement was almost perfect for CT (ICC, 0.96) and substantial for MRI (ICC, 0.76). Intra-reader agreement was almost perfect for both modalities (ICC, CT, 0.99; MRI, 0.94). Bland-Altman analysis showed no statistically significant differences between CT and MRI measurements with a slight positive bias for MRI (mean pooled difference, 1.1°; p = 0.058; limits of agreement, -4.7 to 6.8°) and almost perfect agreement for both readers (ICC, 0.86-0.90).

conclusionMRI measures acetabular cup version with excellent reliability and close agreement with CT, reinforcing MRI's role in postoperative THA evaluation.

Indexed as

AcetabulumArthroplasty, Replacement, HipHip ProsthesisMagnetic Resonance ImagingTomography, X-Ray ComputedAgedArtifactsFemaleHumansMaleMetalsMiddle AgedReproducibility of ResultsRetrospective StudiesMetalsAcetabular anteversion measurementComputed tomographyMagnetic resonance imagingMetal artifact reduction sequencesProsthetic hip imagingTotal hip arthroplasty

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.