ArticleSkeletal radiology2026
Femoral neck-parallel reconstruction enhances correlation between CT-based measurements and dual-energy X-ray absorptiometry for osteoporosis assessment.
Article in Skeletal radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
- Erratum issued
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo evaluate whether femoral neck-parallel reconstruction of CT images improves the correlation with dual-energy X-ray absorptiometry for osteoporosis assessment compared with conventional table-parallel reconstruction. MATERIALS AND
methodsA retrospective analysis was conducted on 174 patients who underwent hip CT and dual-energy X-ray absorptiometry. Two CT image reconstruction methods were compared: femoral neck-parallel and table-parallel methods. CT values were extracted from cancellous bone regions in the femoral neck corresponding to the area measured by DXA. Correlation coefficients between CT values and dual-energy X-ray absorptiometry-derived bone mineral density and T-scores were calculated. A stratified analysis by femoral neck-to-table angle (< 5° vs. ≥ 5°) was performed. Receiver operating characteristic (ROC) curve analysis was performed to compare the ability of each method to discriminate between patients with and without low bone mass (defined as osteoporosis or osteopenia).
resultsCT values from the femoral neck-parallel method showed significantly stronger correlations with bone mineral density (r = 0.74) and T-score (r = 0.77) than those from the table-parallel method (bone mineral density: r = 0.66, T-score: r = 0.71) (p = 0.001 for both). In patients with ≥ 5° misalignment, the femoral neck-parallel method showed significantly higher correlation coefficients than the table-parallel method (bone mineral density, p < 0.001; T-score, p = 0.005). ROC curve analysis revealed that the area under the curve for detecting low bone mass was higher in the femoral neck-parallel method (0.87) than in the table-parallel method (0.83) (p = 0.012).
conclusionsFemoral neck-parallel reconstruction significantly improves the correlation between CT values and dual-energy X-ray absorptiometry for low bone mass assessment compared to table-parallel reconstruction.