Evidence map›Paper›PMID 41670904›Full record

ArticleJournal of fluorescence2026

Novel Quinoline Chemosensor with Dual-Mode Fluorescence and DFT-Backed Mechanism for Mercury(II) Sensing.

Gasser M Khairy, Bader M Alanazi, Yasser A Attia, Mohamed M Aboelnga, Randa M Abdel Hameed

Abstract read
In one paragraph

Article in Journal of fluorescence, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Gasser M KhairyChemistry Department, Faculty of Science, Suez Canal University, Ismailia, 41522, Egypt. gasser_mostafa@science.suez.edu.eg.
Bader M AlanaziDepartment of Chemistry, Faculty of Science, Cairo University, Giza, 12613, Egypt.
Yasser A AttiaNational Institute of Laser Enhanced Sciences Cairo University, Giza, 12613, Egypt.
Mohamed M AboelngaChemistry Department, Faculty of Science, Damietta University, New Damietta, 34517, Egypt.
Randa M Abdel HameedDepartment of Chemistry, Faculty of Science, Cairo University, Giza, 12613, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Mercury (Hg²⁺) contamination poses a significant threat to environmental and human health, necessitating the development of sensitive and selective detection methods. In this study, we report the design and application of a novel quinoline-based chemosensor, HMQC, for the detection of Hg²⁺ in aqueous environments. The probe exhibits dual fluorescence behavior, with quenching at acidic pH (pH 5) and enhancement at neutral pH (pH 7), enabling both qualitative and quantitative detection of Hg²⁺. Under optimized conditions at pH 7, HMQC demonstrated a broad linear range (4.84–50 nM), a low limit of detection (LOD) of 1.47 nM, and high selectivity toward Hg²⁺ over competing metal ions. At pH 5, the probe showed effective quenching with a linear range of 3.09–15 µM and an LOD of 0.93 µM, making it suitable for environments with higher mercury concentrations. The practical utility of HMQC was validated by detecting Hg²⁺ in spiked real water samples with recovery rates ranging from 92% to 108% and relative standard deviations (RSD) below 5%. The probe’s reversibility and reusability were confirmed through successive binding and displacement cycles with EDTA, highlighting its robustness for real-time and continuous monitoring. The adaptability of HMQC under different pH conditions aligns with international water quality standards, such as the World Health Organization (WHO) and European Union (EU) limits for mercury in drinking water (1 µg/L or 5 nM), demonstrating its suitability for environmental and industrial applications. Moreover, DFT calculations have been conducted to obtain atomistic insights into the binding complex and the quenching mechanism. This work provides a versatile and efficient platform for mercury detection, combining high sensitivity, selectivity, and robust performance in complex matrices. The dual fluorescence response of HMQC represents a novel approach in chemosensor design, offering significant potential for future advancements in environmental monitoring and public health protection. *Corresponding Authors. Gasser M. Khairy: gasser_mostafa@science.suez.edu.eg.

Indexed as

ChemosensorDFT calculationsEnvironmental monitoringMercury detection (Hg²⁺)Selectivity and sensitivityWater quality assessment

Identifiers

PMID41670904
PMCPMC12992395

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.