Evidence map›Paper›PMID 41669671›Full record

ArticleFrontiers in surgery2026

Combining 3D printing technology with customized metal plates for the treatment of long segment femoral shaft comminuted fractures.

Rongda Xu, Yingying Liang, Hanfei Liu, Jiahui Li, Xueting Zhou, Ming Sun, Hongliang Tu, Zelin Zhang, Siyu Duan, Zhencun Cai

Abstract read
In one paragraph

Article in Frontiers in surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Rongda Xu *Department of Orthopedic Surgery, The Second Affiliated Hospital of Shenyang Medical College, Shenyang, Liaoning, China.
Yingying Liang *Department of Orthopedic Surgery, Shengjing Hospital of China Medical University, Shenyang, Liaoning, China.
Hanfei Liu *Department of Orthopedic Surgery, Central Hospital Affiliated to Shenyang Medical College, Shenyang, Liaoning, China.
Jiahui LiDepartment of Orthopedic Surgery, Central Hospital Affiliated to Shenyang Medical College, Shenyang, Liaoning, China.
Xueting ZhouDepartment of Orthopedic Surgery, Central Hospital Affiliated to Shenyang Medical College, Shenyang, Liaoning, China.
Ming SunDepartment of Orthopedic Surgery, The Second Affiliated Hospital of Shenyang Medical College, Shenyang, Liaoning, China.
Hongliang TuDepartment of Orthopedic Surgery, The Second Affiliated Hospital of Shenyang Medical College, Shenyang, Liaoning, China.
Zelin ZhangDepartment of Orthopedic Surgery, The Second Affiliated Hospital of Shenyang Medical College, Shenyang, Liaoning, China.
Siyu DuanDepartment of Orthopedic Surgery, The Second Affiliated Hospital of Shenyang Medical College, Shenyang, Liaoning, China.
Zhencun CaiDepartment of Orthopedic Surgery, The Second Affiliated Hospital of Shenyang Medical College, Shenyang, Liaoning, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: This study aims to evaluate the clinical value of combining 3D printing technology with customized metal plates in the treatment of long-segment femoral shaft comminuted fractures. Methods: A retrospective study was conducted on 36 patients with long-segment femoral shaft comminuted fractures who were treated at our hospital between September 2020 and September 2023. Patients were divided into two groups: the conventional group (18 patients), treated with limited open reduction and intramedullary nailing, and the 3D printing group (18 patients), which utilized 3D-printed models and customized metal plates for assisted internal fixation. Intraoperative evaluation metrics included surgical time, number of fluoroscopy exposures, and intraoperative blood loss. Postoperative evaluation metrics included the time to weight-bearing initiation, time to full weight-bearing, and fracture healing time. At 3 months post-operation and at the final follow-up, evaluations were conducted on the knee flexion-extension range of motion (ROM), hospital for special surgery (HSS) score, hip flexion-extension ROM, Harris score, visual analogue scale (VAS) score, and the occurrence of complications. At the final follow-up, lateral displacement, angular deformity, shortening deformity, and the modified radiographic union score for tibia (mRUST) score of the fracture site were evaluated. Results: The 3D printing group had significantly shorter surgical time and fewer fluoroscopy exposures (both Conclusion: Combining 3D printing technology with customized metal plates in treating long-segment femoral shaft comminuted fractures improves surgical efficiency, fracture reduction and healing quality, and promotes functional recovery.

Indexed as

3D printing technologycomminutedcustomized metal platesfemoral shaft fractureslong segment

Identifiers

PMID41669671
PMCPMC12883651

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.