Rapid antithrombin assay from human blood plasma utilizing smartphone-based flow observation on paper chips.

Ashley K Mathews, Allison J Eby, Jocelyn Reynolds, Raymond K Wong, Jeong-Yeol Yoon

Abstract read
In one paragraph

Article in PLOS digital health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ashley K MathewsDepartment of Pharmacology, Perfusion Sciences Program, College of Medicine, The University of Arizona, Tucson, Arizona, United States of America.
Allison J EbyDepartment of Pharmacology, Perfusion Sciences Program, College of Medicine, The University of Arizona, Tucson, Arizona, United States of America.
Jocelyn ReynoldsDepartment of Biomedical Engineering, The University of Arizona, Tucson, Arizona, United States of America.
Raymond K WongDepartment of Pharmacology, Perfusion Sciences Program, College of Medicine, The University of Arizona, Tucson, Arizona, United States of America.
Jeong-Yeol YoonDepartment of Biomedical Engineering, The University of Arizona, Tucson, Arizona, United States of America.ORCID https://orcid.org/0000-0002-9720-6472

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Antithrombin (AT) is a protein that plays a critical role in regulating the coagulation cascade. Currently available methods for detecting AT levels are not portable, rapid, or simple enough to be used in urgent and clinical settings. This work presents a novel method for detecting AT levels from human blood through the smartphone-based capillary flow observation on paper chips. Assays were initially conducted with AT-spiked phosphate-buffered saline (PBS), demonstrating high linearity (R² = 0.988) between flow velocity and the logarithm of AT concentration (ng/mL), with a linear range of up to 12 ng/mL. Assays were also conducted on diluted human plasma samples, showing increasing, plateaued, and decreasing regions over the AT concentrations, respectively. A high linearity (R2 = 0.973) was observed within the linear range up to 19 ng/mL. This behavior mirrors the classic Heidelberger-Kendall antibody-antigen precipitation assay, characterized by a bell-shaped curve, despite substantial differences in assay mechanisms and a concentration range that is orders of magnitude lower. To validate this similarity, we directly measured the extent of particle immunoagglutination on the paper chips using a smartphone-based fluorescence microscope and confirmed the same bell-shaped curve. These results indicate that capillary flow velocity is positively correlated with the extent of particle immunoagglutination. Using multiple human blood samples (n = 14; each subject was tested three times), the smartphone-based flow velocity AT assay was compared with ELISA, and a strong correlation was observed. The assay was essentially near-real-time, as only the first 35 frames (1.17 seconds) of data were required, provided that the antibody-conjugated particles were pre-loaded on the paper chip before the assay. It requires only a paper chip and a smartphone, and involves only one pipetting step for sample loading. This assay could one day address the critical need for determining AT deficiency and support clinicians in managing patients' anticoagulation status.