ArticleMedical physics2026
Combining flat-panel imaging with internal BB markers for precise HDR brachytherapy source localization: A simulation study.
Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
backgroundHigh Dose Rate (HDR) brachytherapy delivers concentrated radiation to the tumor by placing a high-dose-rate radioactive source directly inside the target. However, the sharp dose falloff also increases susceptibility to errors and uncertainties. PURPOSE: To enhance source localization accuracy relative to room coordinates and the implant, we optimize the design of a flat-panel-based source localization system for HDR brachytherapy.
methodsGamma rays from the Ir-192 Flexisource were simulated with Monte Carlo for image reconstruction. A 50 × 50 cm
resultsRelative to the room coordinates using the couch-BBs, the proposed system achieves 0.78 mm accuracy. Localization error increases with larger BSD and smaller BDD, ranging from 0.3-2.5 mm (BSD: 10-30 cm) and 0.3-1.2 mm (BDD: 30-10 cm). Introducing implant motion (15 mm translation, 10
conclusionThe study demonstrates the feasibility of using a flat-panel detector, couch-attached markers, and a dummy wire for robust localization of the HDR brachytherapy source relative to both the room coordinates and the implant.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.