Evidence map›Paper›PMID 41664783›Full record

ArticleCureus2026

Component Asymmetry in Robotic-Assisted Bilateral Total Knee Arthroplasty.

Taiceer Abdulwahab, Subhashree Ravi, Hesham Alkhateeb, Ahmed Elhemaky, Karl F Almqvist, Saeed Althani, Ali Albelooshi

Abstract read
In one paragraph

Article in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Taiceer AbdulwahabOrthopaedic Surgery, King's College Hospital London, Dubai, ARE.
Subhashree RaviSurgery, Hull York Medical School, York, GBR.
Hesham AlkhateebOrthopaedic Surgery, Emirates Specialty Hospital, Dubai, ARE.
Ahmed ElhemakyOrthopaedic Surgery, Mediclinic Parkview Hospital, Dubai, ARE.
Karl F AlmqvistOrthopaedics, Mediclinic City Hospital, Dubai, ARE.
Saeed AlthaniOrthopaedic Surgery, Orthocure Medical Center, Dubai, ARE.
Ali AlbelooshiOrthopaedic Surgery, Orthocure Medical Center, Dubai, ARE.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction Accurate sizing of femoral and tibial components is fundamental to achieving successful outcomes in total knee arthroplasty (TKA). Oversizing can increase patellofemoral contact forces and restrict flexion, whilst undersizing may result in instability. Although conventional TKA is well established, robotic-assisted systems provide enhanced alignment accuracy, individualised planning, and reduced periarticular soft-tissue injury. Bilateral TKA is increasingly performed in Middle Eastern populations, where knee anthropometry differs from Western cohorts. Previous studies in conventional bilateral TKA have demonstrated notable asymmetry between femoral and tibial components. The aim of this study was to determine the frequency of component asymmetry in simultaneous bilateral robotic-assisted TKA using the Navio robotic system in a Middle Eastern population. Methods A retrospective review was undertaken of all patients undergoing primary, uncomplicated simultaneous bilateral robotic-assisted TKA at Mediclinic City Hospital, Dubai, UAE, between January 2018 and January 2020. Only procedures performed by a single surgeon were included. Demographic data, body mass index (BMI), and component sizes were recorded. All procedures utilised implants from the Anthem Total Knee System (Smith & Nephew, London, UK), designed with standard and narrow femoral options to minimise medio-lateral overhang. Symmetry of femoral, tibial, polyethylene, and patellar components was assessed. Standard perioperative protocols for infection prevention, thromboprophylaxis, and enhanced recovery rehabilitation were employed. Results A total of 140 patients (78.6% female patients, mean age 70.4 ± 8.8 years) were included. The mean BMI fell within the overweight to obese range. Femoral components were identical in 132 patients (95%), with asymmetry present in eight patients (5%). Of these, six patients (4%) demonstrated a one-size difference, and eight exhibited variation in femoral component width (standard versus narrow). All tibial baseplates, polyethylene inserts, and patellar components were symmetrical across both knees (100%). Conclusion This is the largest series to date reporting on component symmetry in robotic-assisted bilateral TKA in a Middle Eastern population. The findings demonstrate a high degree of femoral and tibial component symmetry, with only 5% of patients requiring femoral asymmetry and none requiring tibial or patellar asymmetry. Compared with prior reports of conventional bilateral TKA in similar populations, robotic-assisted TKA showed markedly lower asymmetry rates. These results suggest that robotic technology improves the accuracy of component sizing and alignment, reduces mismatch rates, and may enhance long-term functional outcomes. Further prospective studies with functional and radiological endpoints are recommended to corroborate these findings and explore cost-effectiveness in the wider clinical practice.

Indexed as

component alignmentknee arthroplastyorthopaedic navigationprimary knee replacementrobotic knee surgery

Identifiers

PMID41664783
PMCPMC12883243

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.