Evidence map›Paper›PMID 41664668›Full record

ArticleCureus2026

Functional Outcomes and Early Complications Following Volar Locking Plate Fixation of Unstable Distal Radius Fractures: A Minimum Two-Year Follow-Up Study.

Saran Malisorn

Abstract read
In one paragraph

Article in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Saran MalisornOrthopaedics, Naresuan University, Phitsanulok, THA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background Volar locking plate fixation has become the preferred operative treatment for unstable distal radius fractures because it allows stable fixation and early mobilization. However, long-term clinical outcomes and early complications in Asian populations treated in routine practice remain less well documented. Methods This retrospective cohort study included 40 consecutive adult patients with unstable distal radius fractures treated with volar locking plates by a single hand and wrist surgeon at a university hospital between January 2012 and December 2021. Patients met predefined radiographic criteria for instability and were followed for at least two years. Radiographic parameters (radial inclination, palmar tilt, and ulnar variance) were assessed preoperatively, immediately after surgery, at three months, and at ≥2 years. Wrist range of motion, grip strength, Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH), Patient-Rated Wrist Evaluation (PRWE), and pain visual analog scale (VAS) scores were recorded preoperatively, at two weeks, three months, and at ≥2 years. Early complications within three months (carpal tunnel syndrome, median nerve palmar branch injury, and extensor pollicis longus rupture) were retrieved from medical records. Paired t-tests were used to compare changes over time. Results A total of 40 patients were included (mean age, 55.4 years), of whom 26 (65.0%) were women. Radiographic alignment improved after fixation and was maintained at ≥2 years. Patient-reported outcomes (QuickDASH and PRWE), pain, range of motion, and grip strength improved progressively, with minimal disability and pain at long-term follow-up. Early symptoms consistent with carpal tunnel syndrome occurred in seven (17.5%) patients; no median nerve palmar branch injury, extensor pollicis longus rupture, or flexor pollicis longus rupture was identified. Conclusions In this single-surgeon retrospective cohort with a minimum two-year follow-up, volar locking plate fixation for unstable distal radius fractures achieved durable restoration of radiographic alignment and progressive improvement in wrist-related pain and function. Patient-reported outcomes, range of motion, and grip strength improved over time, and major complications were uncommon; early symptoms consistent with carpal tunnel syndrome occurred in seven (17.5%) patients, and no extensor pollicis longus or flexor pollicis longus rupture was identified. Overall, these findings support volar locking plate fixation as a reliable treatment option for unstable distal radius fractures in routine clinical practice.

Indexed as

carpal tunnel syndromecomplicationsdistal radius fractureprwequickdashvolar locking plate

Identifiers

PMID41664668
PMCPMC12883004

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.