Evidence map›Paper›PMID 41662596›Full record

ArticleJournal of the American Academy of Orthopaedic Surgeons. Global research & reviews2026

Thicker Polyethylene Bearings Offer Equivalent Patient-reported Outcomes.

Weston Carpenter, Sara Strecker, Leah Goldberg, Durgesh Nagarkatti, Mark Shekhman, Robert Carangelo, Dan Witmer

Abstract read
In one paragraph

Article in Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Thicker polyethylene inserts for varus deformity versus thinner inserts for flexion contracture in total knee arthroplasty: a retrospective comparative study.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Weston CarpenterFrom the University of Connecticut Medical School, University of Connecticut Health Center, Farmington (Dr. Carpenter); the Bone & Joint Institute, Hartford Hospital, Hartford (Dr. Strecker, Goldberg, Dr. Nagarkatti, Dr. Shekhman, Dr. Carangelo, and Dr. Witmer); and the Orthopedic Associates of Hartford, Hartford, CT (Dr. Nagarkatti, Dr. Shekhman, Dr. Carangelo, and Dr. Witmer).
Leah Goldberg
Durgesh Nagarkatti
Mark Shekhman
Robert Carangelo
Dan Witmer

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPolyethylene bearing (PEB) thickness in total knee arthroplasty (TKA) is a critical factor in achieving joint stability and soft-tissue balance. Despite long-standing surgical preference for thinner bearings, the effect of thicker PEBs on patient-reported outcomes (PROs) remains unclear. The purpose of this study was to compare patient-reported and surgical outcomes between patients receiving thicker (≥13 mm) and thinner (<13 mm) PEBs in primary TKA.

methodsWe retrospectively analyzed 2,751 patients who underwent primary TKA for osteoarthritis at a single high-volume orthopaedic hospital between 2020 and 2023. Patients were divided into two groups based on PEB thickness. Outcomes included PROs (Knee Injury and Osteoarthritis Outcome Score for Joint Replacement; Forgotten Joint Score), inpatient pain and mobility, surgical data, and 90-day postoperative complications. Multivariate statistical methods were used for analysis.

resultsPEB thickness was not associated with clinically notable differences in PROs. At 6 and 12 months, Knee Injury and Osteoarthritis Outcome Score for Joint Replacement and pain scores were slightly better in the ≥13-mm group (P < 0.05), but differences were not clinically meaningful. Subgroup analysis showed these differences were notable only in male patients. Forgotten Joint Scores and early complication rates were equivalent between groups. DISCUSSION: The use of thicker PEBs (≥13 mm) in TKA does not negatively affect PROs or early surgical outcomes and may slightly improve midterm pain and function in male patients. These findings support the selective use of thicker bearings when required for intraoperative balance without compromising patient satisfaction or recovery.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneePatient Reported Outcome MeasuresPolyethyleneProsthesis DesignAgedFemaleHumansMaleMiddle AgedRetrospective StudiesTreatment OutcomePolyethylene

Identifiers

PMID41662596
PMCPMC12879950

What OpenQuestion holds

Textmetadata
LicenceCC BY-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.