Evidence map›Paper›PMID 41660542›Full record

ArticleJSES international2026

Bot vs. doc-who is better at reading proximal humerus fracture x-rays?

Kyle K Obana, Mark Ren, Andrew J Luzzi, Matthew R LeVasseur, Hasani W Swindell, William N Levine

Abstract read
In one paragraph

Article in JSES international, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kyle K ObanaDepartment of Orthopedic Surgery, Columbia University Irving Medical Center, New York, NY, USA.
Mark RenDepartment of Orthopedic Surgery, Columbia University Irving Medical Center, New York, NY, USA.
Andrew J LuzziDepartment of Orthopedic Surgery, Columbia University Irving Medical Center, New York, NY, USA.
Matthew R LeVasseurDepartment of Orthopedic Surgery, Columbia University Irving Medical Center, New York, NY, USA.
Hasani W SwindellDepartment of Orthopedic Surgery, Columbia University Irving Medical Center, New York, NY, USA.
William N LevineDepartment of Orthopedic Surgery, Columbia University Irving Medical Center, New York, NY, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Artificial intelligence is becoming increasingly utilized as a source of convenient, efficient, and cost-effective information. Considering the potential utility of ChatGPT as an adjuvant in clinical decision making, the current study evaluates (1) the accuracy of ChatGPT-5 at evaluating shoulder x-rays containing either normal or proximal humerus fracture (PHFx) diagnoses and (2) interrater reliability between ChatGPT and orthopedic surgeons at different levels of training. Methods: The Stanford University Musculoskeletal Radiographs publicly accessible dataset was utilized, and 70 x-rays (35 PHFx, 35 normal) were analyzed after inclusion and exclusion criteria were applied. X-rays were reviewed independently by an orthopedic surgery junior resident, senior resident, shoulder/elbow fellow, and shoulder/elbow fellowship-trained attending. X-rays for each patient were uploaded to ChatGPT-5 and questions were asked using a response-based algorithm. Results: ChatGPT-5 demonstrated a sensitivity of 61.8%, specificity of 74.3%, and an overall accuracy of 67.1% for PHFx x-rays. ChatGPT incorrectly diagnosed 25.7% of normal x-rays with a fracture or dislocation. ChatGPT incorrectly diagnosed 23.5% of isolated PHFx x-rays as normal, 8.8% with an isolated glenohumeral dislocation without fracture, and 5.7% with a PHFx dislocation. Inter-rater reliability for ChatGPT was slight for displaced parts and poor for fractured part, Neer parts, and located glenohumeral joint. Junior and senior residents had moderate to substantial agreement with the attending reads (fractured part, displaced parts, Neer parts), while the fellow had substantial to almost perfect agreement. Conclusion: This study demonstrates that ChatGPT-5 is highly inaccurate at identifying PHFx on shoulder x-rays, characterizing the fracture patterns, and providing accurate interpretations of shoulder x-rays. Over-reliance on generative artificial intelligence to guide clinical decisions risks harm to the patients and should be approached with limited credence.

Indexed as

AIArtificial intelligenceChatGPTNeerProximal humerus fractureRadiographsShoulderXR

Identifiers

PMID41660542
PMCPMC12876602

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.