Evidence map›Paper›PMID 41660298›Full record

ArticleOrthopaedic journal of sports medicine2026

Bone Quality Positively Correlates With Biomechanical Strength of All-Suture Anchors Utilized in Biceps Tenodesis.

Andrew D Posner, Dave T Huang, Andrew Nakla, Ajith Malige, Thay Q Lee, Orr Limpisvasti, Melodie F Metzger

Abstract read
In one paragraph

Article in Orthopaedic journal of sports medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Andrew D PosnerCedars-Sinai Kerlan-Jobe Institute, Los Angeles, California, USA.ORCID https://orcid.org/0000-0002-6021-3273
Dave T HuangDepartment of Orthopaedic Surgery, Cedars-Sinai, Los Angeles, California, USA.
Andrew NaklaDepartment of Orthopaedic Surgery, Cedars-Sinai, Los Angeles, California, USA.
Ajith MaligeCedars-Sinai Kerlan-Jobe Institute, Los Angeles, California, USA.ORCID https://orcid.org/0000-0002-3984-4804
Thay Q LeeOrthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, California, USA.
Orr LimpisvastiCedars-Sinai Kerlan-Jobe Institute, Los Angeles, California, USA.
Melodie F MetzgerDepartment of Orthopaedic Surgery, Cedars-Sinai, Los Angeles, California, USA.ORCID https://orcid.org/0000-0001-8892-7035

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: All-suture anchors (ASAs) are increasingly used in biceps tenodesis (BT), and their fixation strength may vary with cortical bone and surgical position. Defining the influence of bone mineral density (BMD) on ASA pullout strength and failure mode across the high bicipital groove (HG), low bicipital groove suprapectoral position (SUP), and subpectoral (SUB) positions may allow for optimal anchor placement. Hypothesis: ASA biomechanical characteristics at each region of the bicipital groove would improve with increasing regional BMD. Study Design: Controlled laboratory study. Methods: ASAs measuring 2.6 mm were inserted into the HG, SUP, and SUB positions of the bicipital groove of 12 cadaveric specimens. Local measures of bone quality around each anchor were evaluated using micro-computed tomography. Afterward, each ASA was biomechanically loaded to failure to determine the ultimate pullout strength and mode of failure. Repeated-measures correlations were calculated to determine the relationship between measures of bone quality and pullout strength. Results: Mean load to failure of ASAs placed in the HG, SUP, and SUB positions were 370.7 ± 111.2 N (95% CI, 300.0-441.3 N), 600.5 ± 120.8 N (95% CI, 523.8-677.3 N), and 668.1 ± 117.2 N (95% CI, 593.6-742.5 N), respectively. Mean load to failure of ASAs placed in the SUP and SUB positions was significantly greater than in the HG position ( Conclusion: ASA pullout strength was correlated with local cortical BMD. ASA fixation strength and BMD were robust in all tested regions of the bicipital groove but were greatest in the SUP and SUB positions. Clinical Relevance: ASAs can effectively be placed throughout the bicipital groove. ASAs in all 3 tested positions can withstand not only the force reportedly placed on the anchor by the native biceps but also the force previously reported to cause failure at the suture-biceps tendon interface. These biomechanical findings add to the growing clinical and basic science evidence supporting the use of ASA for BT.

Indexed as

all-suture anchorbiceps tenodesisbicipital groovebiomechanical studybone mineral densitypullout strengthsubpectoralsuprapectoral

Identifiers

PMID41660298
PMCPMC12873105

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.