Evidence map›Paper›PMID 41660276›Full record

ArticleFrontiers in cell and developmental biology2026

The effect of 4.3 GHz high-power microwave exposure on human corneal epithelial cells.

Anning Gao, Xuelong Zhao, Shuang Wu, Xiaoman Liu, Xinyu Wang, Luhao Tan, Zhihui Li, Guofu Dong, Changzhen Wang

Abstract read
In one paragraph

Article in Frontiers in cell and developmental biology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Anning GaoBasic Medical College of Anhui Medical University, Hefei, China.
Xuelong ZhaoBeijing Key Laboratory for Radiobiology, Beijing Institute of Radiation Medicine, Beijing, China.
Shuang WuBeijing Key Laboratory for Radiobiology, Beijing Institute of Radiation Medicine, Beijing, China.
Xiaoman LiuBeijing Key Laboratory for Radiobiology, Beijing Institute of Radiation Medicine, Beijing, China.
Xinyu WangBeijing Key Laboratory for Radiobiology, Beijing Institute of Radiation Medicine, Beijing, China.
Luhao TanBeijing Key Laboratory for Radiobiology, Beijing Institute of Radiation Medicine, Beijing, China.
Zhihui LiBeijing Key Laboratory for Radiobiology, Beijing Institute of Radiation Medicine, Beijing, China.
Guofu DongBasic Medical College of Anhui Medical University, Hefei, China.
Changzhen WangBeijing Key Laboratory for Radiobiology, Beijing Institute of Radiation Medicine, Beijing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: High-power microwave (HPM) exposure can produce biological effects in cells, but the specific characteristics and mechanisms of these effects in ocular tissues remain poorly defined. This study aimed to investigate the biological responses of human corneal epithelial cells (HCE-T) to 4.3 GHz HPM exposure, with a focus on moderate-dose effects. Methods: HCE-T cells were exposed to 4.3 GHz HPM at average specific absorption rates (SARs) of 1.64, 3.28, and 8.2 W/kg. Cellular responses were evaluated by measuring cell viability, reactive oxygen species (ROS) generation, mitochondrial membrane potential, and apoptosis at multiple time points. Transcriptomic analysis was performed to identify underlying molecular pathways. Results: Moderate-dose exposure (3.28 W/kg) resulted in the most pronounced cellular effects, including early and significant ROS elevation, marked collapse of mitochondrial membrane potential, the highest apoptosis rate, and sustained inhibition of proliferation. Transcriptomic profiling showed strong suppression of the mTOR signaling pathway, upregulation of TSC2, and activation of Polycomb-mediated chromatin remodeling, suggestive of autophagy induction and irreversible cell cycle arrest. In contrast, low-dose exposure (1.64 W/kg) primarily activated DNA repair and adaptive pathways, while high-dose exposure (8.2 W/kg) predominantly disrupted metabolic and membrane signaling with a trend toward recovery. Discussion: These findings demonstrate that moderate-dose 4.3 GHz HPM exposure induces a uniquely strong stress response in HCE-T cells, characterized by oxidative stress, mitochondrial dysfunction, and activation of stress-related signaling pathways. These results highlight the importance of considering specific exposure conditions in assessing HPM bioeffects and ocular safety.

Indexed as

apoptosiscorneal epithelial cellshigh-power microwavemitochondrial dysfunctionMTOR signalingnon-thermal effectsoxidative stress

Identifiers

PMID41660276
PMCPMC12872831

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.