Evidence map›Paper›PMID 41656966›Full record

ArticleCatheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions2026

The Verification of Co-Axiality of the Three Self-Expanding Transcatheter Aortic Valve Systems According to the Difference in Shaft Spine.

Yun Teng, Yusuke Enta, Makoto Saigan, Natsuko Satomi, Yuta Kobayashi, Masaki Nakashima, Momo Kosuga, Manabu Maeda, Yusuke Toki, Yoshiko Munehisa and 4 more

Abstract readComparative Study
In one paragraph

Article in Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Yun TengDivision of Cardiovascular Medicine, Sendai Kosei Hospital, Sendai, Japan.
Yusuke EntaDivision of Cardiovascular Medicine, Sendai Kosei Hospital, Sendai, Japan.ORCID 0000-0003-1931-1012
Makoto SaiganDivision of Cardiovascular Medicine, Sendai Kosei Hospital, Sendai, Japan.
Natsuko SatomiDivision of Cardiovascular Medicine, Sendai Kosei Hospital, Sendai, Japan.
Yuta KobayashiDivision of Cardiovascular Medicine, Sendai Kosei Hospital, Sendai, Japan.
Masaki NakashimaDivision of Cardiovascular Medicine, Sendai Kosei Hospital, Sendai, Japan.
Momo KosugaDivision of Cardiovascular Medicine, Sendai Kosei Hospital, Sendai, Japan.
Manabu MaedaDivision of Cardiovascular Medicine, Sendai Kosei Hospital, Sendai, Japan.
Yusuke TokiDivision of Cardiovascular Medicine, Sendai Kosei Hospital, Sendai, Japan.
Yoshiko MunehisaDivision of Cardiovascular Medicine, Sendai Kosei Hospital, Sendai, Japan.
Masaki MiyasakaDepartment of Cardiology, The Jikei University, Tokyo, Japan.
Masataka TaguriDepartment of Health Data Science, Tokyo Medical University, Tokyo, Japan.ORCID 0000-0001-8902-0056
Shigeru ToyodaDepartment of Cardiovascular Medicine, Dokkyo Medical University School of Medicine, Tochigi, Japan.
Norio TadaDivision of Cardiovascular Medicine, Sendai Kosei Hospital, Sendai, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAccurate bioprosthesis implantation depth during transcatheter aortic valve replacement (TAVR) is crucial for optimal outcomes. Self-expanding valves (SEVs) have evolved delivery catheter designs, from a double spine shaft in Evolut PRO+ (PRO + ) to single spine in Evolut FX (FX) and non-spine in Navitor, to improve access deliverability.

aimsTo investigate the influence of different spine structures on valve implantation.

methodsRetrospectively, we investigated 95 severe aortic stenosis patients who underwent transfemoral TAVR using SEVs (PRO + : 41, FX: 21, and Navitor: 33 patients) from January 2021 to July 2023. The implantation depth difference (IDD) between Left Coronary Cusp (LCC) and Non-Coronary Cusp (NCC) was measured angiographically at the point of no recapture, defined as subtracting NCC implantation depth from LCC. Positive IDD indicates deeper LCC than NCC, also shown as "vertical axis." Whereas negative IDD indicates shallower LCC than NCC, demonstrated as "horizontal axis."

resultsIDD at the point of no recapture showed significant difference among three groups (PRO + : 2.42 [0.81-3.42], FX: 1.01 [0.29-1.77], Navitor: -2.16[-2.74- (-1.14)] mm, p < 0.001, PRO + > FX/Navitor, FX > Navitor). PRO+ had a positive IDD, indicating deeper LCC implantation. Navitor had a negative IDD, demonstrating shallower implantation on LCC, and FX showed co-axial implantation.

conclusionPRO+ with double spines showed vertical axis, Navitor with non-spine showed horizontal axis, whereas FX demonstrated co-axiality at the point of no recapture. This knowledge may help refine the manipulation of procedural implantation based on the shaft rigidity in each device to gain co-axiality.

Indexed as

Aortic ValveAortic Valve StenosisBioprosthesisHeart Valve ProsthesisTranscatheter Aortic Valve ReplacementAgedAged, 80 and overFemaleHumansMaleProsthesis DesignRetrospective StudiesSeverity of Illness IndexTreatment Outcomeaortic stenosisco‐axialityself‐expanding valvetranscatheter aortic valve replacement

Identifiers

PMID41656966
PMCPMC13043791

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.