Evidence map›Paper›PMID 41656815›Full record

ArticleZhong nan da xue xue bao. Yi xue ban = Journal of Central South University. Medical sciences2025

[Value of small bowel stenosis in Crohn

Ying Mei, Yuanyuan Yang, Xuemei Li, Chang Xin, Feng Gao

Abstract readEnglish Abstract
In one paragraph

Article in Zhong nan da xue xue bao. Yi xue ban = Journal of Central South University. Medical sciences, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ying MeiDepartment of Ultrasound, Third Affiliated Hospital, Sun Yat-sen University, Guangzhou 510630. yingmei_9926@163.com.
Yuanyuan YangDepartment of Gastroenterology, Third Xiangya Hospital, Central South University, Changsha 410013.
Xuemei LiDepartment of Ultrasound, Third Xiangya Hospital, Central South University, Changsha 410013, China.
Chang XinDepartment of Ultrasound, Third Xiangya Hospital, Central South University, Changsha 410013, China.
Feng GaoDepartment of Ultrasound, Third Xiangya Hospital, Central South University, Changsha 410013, China. gf0731@csu.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesSmall bowel stenosis constitutes a frequent complication of Crohn's disease (CD). Early diagnosis of small bowel stenosis can guide individualized treatment, help avoid intestinal obstruction, and improve prognosis. This study aims to investigate the clinical value of small intestinal contrast ultrasound (SICUS) for diagnosing small bowel stenosis in CD patients, and to provide additional evidence for determining the insertion route of double-balloon endoscopy (DBE).

methodsThe results of SICUS, DBE, and computed tomographic enterography (CTE) from 80 patients with clinical suspicion of CD-associated small bowel stenosis treated at the Third Xiangya Hospital between March 2023 and December 2024 were retrospectively enrolled. The diagnostic accuracy of different examination modalities for small bowel stricture was analyzed. Correlations between the international bowel ultrasound segmental activity score (IBUS-SAS) measured by SICUS, characteristic ultrasound features of small bowel stricture, and DBE-confirmed stricture segments were assessed.

resultsUsing DBE as the reference standard, SICUS showed better diagnostic performance for small bowel stricture than CTE [sensitivity 96.6% vs 91.5%, specificity 76.2% vs 70.0%, area under the curve (AUC) 0.864 vs 0.807]. With DBE as the comparator, SICUS demonstrated excellent agreement in localizing strictured jejunal and ileal segments (Kappa=0.867,

conclusionsSICUS has high sensitivity and specificity for diagnosing active small bowel-stricturing CD, shows strong agreement with DBE results, and performs better than CTE. SICUS enables accurate localization of strictured small bowel segments, and its use as a reference for planning the DBE insertion route is feasible. SICUS ultrasound features including proximal bowel dilation, segmental angulation, and poor peristalsis are independent risk factors for detecting small bowel stricture under DBE.

Indexed as

Crohn DiseaseDouble-Balloon EnteroscopyIntestinal ObstructionIntestine, SmallAdultConstriction, PathologicContrast MediaFemaleHumansMaleMiddle AgedRetrospective StudiesSensitivity and SpecificityUltrasonographyContrast MediaCrohn’s diseasedouble-balloon endoscopysmall bowelstenosisultrasound

Identifiers

PMID41656815
PMCPMC12949865

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.