Evidence map›Paper›PMID 41655153›Full record

ArticleCardiovascular and interventional radiology2026

Intra-osseous Ice Ball Visualization During Cryoablation Using Photon-Counting Detector Computed Tomography: An In-Vivo Swine Pilot Study.

Sivert Kupfer, Konstantin Klambauer, Gilbert Puippe, Miriam Weisskopf, Thomas Pfammatter, Thomas Flohr, Adrian Kobe

Abstract read
PubMed Publisher
In one paragraph

Article in Cardiovascular and interventional radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sivert KupferInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland. sivert.kupfer@usz.ch.
Konstantin KlambauerInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland.
Gilbert PuippeInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland.
Miriam WeisskopfCenter for Surgical Research, University of Zurich, University Hospital of Zurich, Zurich, Switzerland.
Thomas PfammatterInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland.
Thomas FlohrInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland.
Adrian KobeInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the visualization of the ice ball during cryoablation of vertebral bodies and the bony pelvis in an in vivo swine model using virtual non-calcium imaging (VNCa) derived from photon-counting detector computed tomography (PCD-CT). MATERIALS AND

methodsCryoablation was performed at six locations in the spine and pelvis of three live swine. Spectral ultra-high resolution image acquisition using PCD-CT was conducted before ablation and at 2, 4, 6 and 8 min after initiation of the cryoablation cycle. Artifacts were suppressed using iterative metal artifacts reduction. Ice ball visualization within bone and soft tissue was assessed on both, conventional and VNCa images. At each time point the presence and size of the ice ball visualization was evaluated.

resultsA total of 12 needle placements was analyzed. In conventional images the ice ball could not be seen within bone at any time. In contrast, in VNCa images the ice ball became visible after 2 min in all cases. However, the ice ball was less clearly visualized in the soft tissue on VNCa images. Mean ice ball volume at 2, 4, 6, 8 min was 1.6 ± 0.9, 2.8 ± 1.7, 5.5 ± 2.9 and 8.3 ± 3.2 ml in the vertebral bodies and 0.8 ± 0.3, 2.0 ± 0.4, 4.4 ± 0.6, 6.2 ± 1.1 ml in the bony pelvis, respectively.

conclusionPCD-CT enables early visualization of the ice ball within vertebral bodies and the bony pelvis in a swine model using VNCa images.

Indexed as

CryosurgeryIceSpineTomography, X-Ray ComputedAnimalsPhotonsPilot ProjectsSwineIceCryoablationDual source photon counting detector CTIce ballVirtual non calcium images

Identifiers

PMID41655153

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.