ArticleBMC ophthalmology2026
Quantitative assessment of the biomechanical properties of healthy human myopic corneas using Brillouin spectroscopy.
Article in BMC ophthalmology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe importance of corneal biomechanics in ocular health and treatments is well-recognized, but reports on associated factors are inconsistent. We established normative data for corneal stiffness using Brillouin spectroscopy in a large cohort of healthy myopic corneas, exploring potential influences on Brillouin modulus (BM) measurements.
methodsData from 1744 healthy corneas of 885 subjects (17–52 years; 422 females) were retrospectively collected, including intraocular pressure (IOP in mmHg), manifest refraction spherical equivalent (MRSE in dioptres [D]), and Pentacam measurements (central corneal thickness [CCT in µm]), K1 and K2 in D). Corneal scans were recorded on a Brillouin Optical Scanning System (BOSS®) using an automated 10-point pattern to measure Central, Mean, Minimum and Maximum BM values in gigapascals (GPa). Monocular data (primarily right eye) were used for correlations; binocular data for interocular comparisons. Parametric analyses included Pearson correlations, t-tests for sex differences, paired t-tests for interocular differences, and multivariate linear regression to isolate independent factors (e.g., age, sex, CCT, IOP) with interaction terms.
resultsNormative BM values were Central = 2.856 ± 0.053 GPa, Mean = 2.845 ± 0.038 GPa, Min = 2.819 ± 0.046 GPa, and Max = 2.885 ± 0.042 GPa. Interocular comparisons revealed statistically significant but small increases in OS compared to OD for Mean BM (0.003 GPa [95% CI: 0.001–0.005]; OD = 2.855 ± 0.038 GPa, OS = 2.858 ± 0.038 GPa; P = 0.01) and Max BM (0.004 GPa [95% CI: 0.002–0.006]; OD = 2.886 ± 0.042 GPa, OS = 2.890 ± 0.042 GPa; P = 0.003), as well as in K1 and CCT (P < 0.0001). No significant interocular differences were found in Central or Min BM (P ≥ 0.15). Central, Mean and Min BM values correlated significantly with CCT (P ≤ 0.04) but not with IOP, K1, K2, or MRSE (P ≥ 0.20); Max BM did not correlate with any of these clinical parameters (P ≥ 0.07). Males had higher BM values than females (P ≤ 0.006), with effect sizes (d = 0.21) and r = 0.09 –0.1. Regional mapping showed small overall differences in BM values between zones (P = 0.04), with slightly higher values in the Superior region. Multivariate regression confirmed independent associations: Central BM ~ age (β = 0.0008 [95% CI: 0.0001–0.0015], P = 0.04), sex (β = 0.010 [95% CI: 0.003–0.017], P = 0.008), CCT (β = 0.00015 [95% CI: 0.00005–0.00025], P = 0.003); IOP was non-significant (β = 0.0004 [95% CI: −0.0008–0.0016], P = 0.50, R² = 0.048). Age*sex interaction was non-significant (β=−0.0002, P = 0.62). While statistical significance was observed, the correlation coefficients were not large, suggesting a weak linear relationship.
conclusionsNon-contacting Brillouin scans in a large cohort of healthy myopic eyes established robust normative BM standards, revealing associations between corneal stiffness and age, sex, and CCT. These findings provide reference values that enhance diagnostic accuracy for conditions like keratoconus and inform biomechanical assessments in refractive surgery.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.