Evidence map›Paper›PMID 41647811›Full record

ArticleiGIE : innovation, investigation and insights2025

Evaluation of computer-aided detection for gastric cancer using white-light and linked-color imaging: a pilot study.

Takeshi Yasuda, Narutoshi Ando, Tamae Hashimoto, Yoshiaki Kanai, Yoichi Sakamoto, Yuki Endo, Tomohiro Soda, Takako Akazawa, Tsuguhiro Matsumoto, Norihito Yamauchi and 2 more

Abstract read
In one paragraph

Article in iGIE : innovation, investigation and insights, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. How Does Artificial Intelligence-Assisted Endoscopy Impact Upper Gastrointestinal Screening?Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society · 2026
    Article
  4. Impact of Artificial Intelligence-Assisted Endoscopy on Screening for Upper Gastrointestinal Cancer in a Large-Scale Health Screening Facility.Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Takeshi YasudaDepartment Gastroenterology, Akashi City Hospital, Hyogo, Japan.
Narutoshi AndoDepartment Gastroenterology, Akashi City Hospital, Hyogo, Japan.
Tamae HashimotoDepartment Gastroenterology, Akashi City Hospital, Hyogo, Japan.
Yoshiaki KanaiDepartment Gastroenterology, Akashi City Hospital, Hyogo, Japan.
Yoichi SakamotoDepartment Gastroenterology, Akashi City Hospital, Hyogo, Japan.
Yuki EndoDepartment Gastroenterology, Akashi City Hospital, Hyogo, Japan.
Tomohiro SodaDepartment Gastroenterology, Akashi City Hospital, Hyogo, Japan.
Takako AkazawaDepartment Gastroenterology, Akashi City Hospital, Hyogo, Japan.
Tsuguhiro MatsumotoDepartment Gastroenterology, Akashi City Hospital, Hyogo, Japan.
Norihito YamauchiDepartment Gastroenterology, Akashi City Hospital, Hyogo, Japan.
Akira MuramatsuDepartment Gastroenterology, Akashi City Hospital, Hyogo, Japan.
Hiromu KutsumiDepartment Gastroenterology, Akashi City Hospital, Hyogo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Aims: In recent years, the field of endoscopic artificial intelligence has seen significant advancements, largely because of the widespread implementation of deep learning techniques. However, the computer-aided detection (CADe) of the stomach poses significant challenges in clinical practice. Here, we evaluated the performance of a newly developed CADe system, CAD EYE (Fujifilm, Tokyo, Japan), by comparing the frequency of the detection box appearance with white-light imaging (WLI) versus linked-color imaging (LCI) during the process of detecting gastric cancer (GC) and detection of GC with and without CADe. Methods: This single-center observational retrospective study included 105 patients who underwent esophagogastroduodenoscopy (EGD) using CADe and 105 controls selected by propensity-score matching from 600 patients. The primary outcome was to compare the detection box appearance of WLI and LCI during the CADe observation. Secondary outcomes included comparisons of biopsy rates, examination times, and cancer detection rates between groups. Furthermore, we investigated whether the landmark checker could accurately identify the stomach site. Results: CADe exhibited an average of 6.2 false-positive detections per case. False-positive rates were significantly lower with LCI than with WLI (3.48 vs 7.70, Conclusions: This pilot study suggests that CADe, particularly when combined with LCI, may enhance GC detection during EGD without significantly increasing the examination time. Although promising, a high false-positive rate indicates that further optimization is needed.

Identifiers

PMID41647811
PMCPMC12850719

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked