Evidence map›Paper›PMID 41647498›Full record

ReviewClinics in orthopedic surgery2026

Mechanical Performance of Monoaxial Versus Polyaxial Locked Plates for Bone Fracture Repair: A Review.

Radovan Zdero, Emil H Schemitsch, Pawel Brzozowski, Z Shaghayegh Bagheri

Abstract readReview
In one paragraph

Review in Clinics in orthopedic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Radovan ZderoOrthopaedic Biomechanics Lab, Victoria Hospital, London, ON, Canada.ORCID https://orcid.org/0000-0003-0853-3402
Emil H SchemitschOrthopaedic Biomechanics Lab, Victoria Hospital, London, ON, Canada.ORCID https://orcid.org/0000-0002-6435-9069
Pawel BrzozowskiOrthopaedic Biomechanics Lab, Victoria Hospital, London, ON, Canada.ORCID https://orcid.org/0000-0001-6557-7159
Z Shaghayegh BagheriDepartment of Mechanical Engineering, George Mason University, Fairfax, VA, USA.ORCID https://orcid.org/0000-0001-6640-9202

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Widely used "locking" bone fracture plates include standard monoaxial locking plates (MLPs) that allow a single screw insertion angle relative to the plate, as well as newer polyaxial locking plates (PLPs) that permit various screw insertion angles relative to the plate. This is the first review of all studies that compared the mechanical performance of MLPs vs. PLPs. PubMed and Web of Science were searched using the phrases "locked plate polyaxial" and "locked plate variable." Eligibility criteria were applied: mechanical studies, rather than clinical studies, that directly compared MLPs vs. PLPs; bone fracture studies, rather than spine fusion or joint arthroplasty studies; studies published in English; and studies from any date. The 32 studies used experimental testing or computational modeling to compare MLPs vs. different types of PLPs either as implant-bone constructs or isolated implants. The studies employed different bone sites (humerus, radius, femur, tibia, calcaneus, "generic" long bone, implant only), bone qualities (normal, osteoporotic, unknown), fracture sites (proximal, midshaft, distal), and loading modes (axial, bending, torsional). The studies reported mechanical outcome metrics like stiffness, strength, fragment or fracture motion, bone or plate peak stress, and cyclic fatigue life; but no studies reported screw peak stress or bone "stress shielding" risk. The highest mechanical stability was obtained by different implants for the humerus (PLP with "cap" locking), radius (MLP or PLP with "bushing" or "flange" locking), femur (PLP with "cap" locking), tibia (PLP with "bushing" locking), calcaneus (PLP with "flange" or "score" locking), "generic" long bone (PLP with "cap" locking), and isolated implant without bone (PLP with "cap" locking). General trends in results, tabulated numerical data, practical "key concepts," clinical aspects, and recommendations for future work were also given in this review. PLPs almost always provided greater mechanical stability than MLPs for various bone fracture applications, but the specific type of PLP depended on the bone site.

Indexed as

Bone PlatesFracture Fixation, InternalFractures, BoneBiomechanical PhenomenaHumansBiomechanicsLocking platesMonoaxialPolyaxialReview

Identifiers

PMID41647498
PMCPMC12868116

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.